background image

1

.

Cylinder

2.Bracket of cylinder
3.Cylinder cover bracket
4.Cylinder cover
5.Front handle
6.Front handle bracket
7.Front Spindle
8.Reader
9.Mortise
10.Flank sheet
11. Strike
12.Strike box
13. Power Connector
14.PCB Connector
15.Thumb turn
16 Thumb turn cover
17.Battery box
18.Connector to mortise
19.Connector of Power
20.Connector to reader
21. Battery cover

A

B

Lever handing

top view

front view

left hand lever

right hand lever

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

arrow

 

horizontal

21

18

19

20

2

Lock Structure&Installation

Summary of Contents for Zigbee

Page 1: ...Wireless Network System 2 4G Zigbee ...

Page 2: ... Congratulations on your selection of the Hotel Lock System This is a solution that carry out a modern efficient and safe management of the rooms in hotel resorts apartment school lodge office hospitals cruise ship by application of hardware and software Before using the instrument be sure to carefully read through the instructions contained in this manual Please keep all information for future re...

Page 3: ...1 Strike 12 Strike box 13 Power Connector 14 PCB Connector 15 Thumb turn 16 Thumb turn cover 17 Battery box 18 Connector to mortise 19 Connector of Power 20 Connector to reader 21 Battery cover A B Lever handing top view front view left hand lever right hand lever 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 arrow horizontal 21 18 19 20 2 Lock Structure Installation ...

Page 4: ...iliary bolt Deadbolt Thumb knob spindle Cylinder hole Reader Battery box back panel front panel Thumb knob Cylinder cover This is a standard right lever mortise The left mortise in reverse case Battery pack is hide in mortise for mortise model K1L Mortise K3S is the one of several different mortise of all model locks BACK SIDE Connect to battery pack Connect to PCB board FRONT SIDE ROOM OUTSIDE AN...

Page 5: ...draw around the faceplate Remove the mortise and score the outline with a stanley knife to avoiding splitting when chiseling Chisel a rebate to allow the latch to fit flush to the surface Fix the mortise with the screws with the bevel towards the door frame 3 Fix the cylinder Insert the cylinder from front and tight the screws from back by using the inner hexagon screw driver 4 Install front and b...

Page 6: ...Area Networks LR WPANs such as wireless light switches with lamps electrical meters with in home displays consumer electronics equipment via shot range radio needing low rates of data transfer Zigbee is targeted at radio frequency RF applications that require a low data rate long battery life and secure net working Model LA173 Dimension 89X89X33cm Power DC 9V Working current 100mA Wireless Technol...

Page 7: ...ID must differ Neighbouring ID m ustdiffer c o r r i d o r There are only 4 type channel La173 ID XXXX0F01 Channel ID It is strongly recommended that LA173 be placed in a proper position according to their IDs The same channel ID La173 should not be put in neighbouring position due to it may cause the data transfer jam especially in the same floor and neighbor floor 6 Wireless Node Location ...

Page 8: ...Wireless Node X2 7 Wireless Node Location ...

Page 9: ...per location 4 1 Login Operator SYSTEM Password 0 zero 1 Installation of Software Server a Install software Hotel Lock System and server Xentral from software CD b It is recommended that both of applications be installed NOT in disk C the system drive Xentral 3 Build Connection Run Xentral Xentral is a smal tool that make building connection Run it after installation for the first time then exit F...

Page 10: ...ick OK 1 3 Encoder beep once and there comes a window show the hotel code read from Authorized card It is 881A0001 click OK here 1 4 Licence code update window jumped asking input licence code Fill in the licence code given by Xeeder and click Update Register successfully click OK Soft will off automatically again When next running it is a register version and you will see Registered on the head o...

Page 11: ...to start add new IP section 6 In IP Setting menu click Add 4 Select Advenced 7 Fill in the new IP address as following rule Sample If IP of node LA17X is 192 168 1 201 Then add to PC new as 192 168 1 XXX New IP section added completed Same as LA17X node IP 192 168 1 XXX 8 Click Add ATTENTION a The above steps are significant b The aim is to set network segment c PC should have a segment same as no...

Page 12: ...0200F11 MAC 00200F99 SAMPLE Initialization MAC address of lock Users should set an unique MAC address to each lock in hotel lock system software The MAC address is based on the ID of node which is connected with the lock Each node has an unique ID Please check the node case to find MAC 00201810 MAC 00201811 MAC 00201899 ID 00201801 MAC Configuration Rules 11 ...

Page 13: ...uild all room information as following floor by floor and node by node MAC address accords to Node ID Select the correct node as planned Create all room information following is an example What can xeeder hotel lock knows the card in valid term or not Clock of lock Valid term still not effebtive Check in start time Due Check out ent time expiry 09 00 24 00 09 00 24 00 09 00 next day Lock Configura...

Page 14: ...ells you there is some problem with your wireless network Connect Connect very well Lockvents ICON Each lock event will show by icon lively in the status block It shows noting when there is no lock events happen Opening Door is in opening Card It tells you door was opened by card Key It tells you door was opened by key Setting succeed Once you see it you already comlete initalization Status Block ...

Page 15: ...ng timeat a time several minutes ahead of the real when you issue it in Hotel Lock System Then you can do floor by floor by changing a fresh Time card Setting card should be issued in Hotel Lock System It should be 1 pc for 1 room because it saves 1 room ID only We suggest you issue all rooms at one time and mark on each card room ID STEP 4 Activate clock STEP 5 Set room ID STEP 3 Set hotel code I...

Page 16: ...Basic Action 15 ...

Page 17: ...Make check in 16 ...

Page 18: ...t and refused Dead bolt is on Refuse card Dead bolt is on Refuse card Recover unvoided the lost card OK Card s using term has not match Card is in future s date or already expiry or lock s clock is slow or lost Check card s begin and end time If of problem please renew the lock s clock by reading a fresh Time card Card read successfully and unlock able Card read successfully and unlock able Card r...

Page 19: ...www xeederlock com 2006 2015 Xeeder Technology Co Limited All rights reserved Baoan Shenzhen China Tel 0086 755 83663830 Fax 0086 755 22635115 7x24 hours Email sales xeeder com ...