5
#52300000 Battery check + balancer
EN
Battery Connection
·
Parameter settings
Battery Connection
LiXX (2-8 S)
NiXX (4-8 cells)
Rotary
adjuster
Servo
Servo
jack
S
EH and XH type plug on lithium battery packs can be directly connected to the 9-pin connector of the Bat-
teryCheck. The negative pole is always at the top.
NiMH / NiCd batteries are plugged into the upper socket, the negative pole is at the top. Both sockets can
be used simultaneously, the battery to be tested can be selected via the
TYPE
button.
If a LiXX battery is to be measured with only one cell - or NiXX batteries under 4 cells, a separate voltage
supply with min. 5 V DC must be connected at the other input.
Overview Parameter Settings
To program the following parameters, press and hold for
TYPE
key min. 1 sec. to enter the programming
mode. Press
TYPE
briefly to select the next parameter. The values are increased with
MODE
, reduced with
CELL
. Long press
MODE
or
CELL
to change values faster. Press and hold the TYPE button again min. 1
sec. to return to the voltage display.
Voltage
display
Voltage display
Discharge-
cut-off-
voltage
Servotest
frequency
Servotest
signal range
LCD
backlight
Signal tone
Set discharge cut-off voltage
Set Servotest frequency
Set Servotest range
LCD backlight duration
Signal tones ON/OFF
Range: 2 - 4.35 V
Range: 50, 60, 100, 125
200, 250, 300 Hz
Range: 500 - 2500us,
1000 - 2000us
Range:
off, 10 - 60 sec., on
Range: OFF/ON
Press
TYPE
Press
TYPE
Press
TYPE
Press
TYPE
Press
TYPE
Press
TYPE
Voltage
display
Press
TYPE