TROUBLESHOOTING
39
INSTRUCTION MANUAL
?
Touch screen buttons do not function properly
. Remove cover, press the reset
button located in the bottom left corner then accurately touch 3 target centers on
the screen when prompted.
?
Air conditioning turns on in HEAT mode and heating turns on in COOL mode.
Reverse the OB valve (see “Advanced Settings” Page 36).
?
PARTIAL LOCK and FULL LOCK do not function
. You must not touch the screen
for 1 minute for Climatouch
™
to automatically lock.
?
Thermostat appears normal until the screen becomes blank when the com-
pressor or heating system turns on
. You need to connect the “C” wire.
?
I forgot my PIN and cannot unlock the thermostat
. Remove the cover plate, press
the reset button located in the bottom right corner, as soon as the message
“touch to reset password” appears touch the screen, your PIN will be erased and
the thermostat will unlock.
SIMPLE THERMOSTAT MODE
38
XCI
TSZ-1
>>
Your thermostat can also function as a virtual non-programmable thermostat
after it has been switched to a “SIMPLE MODE”.
>>
To enable “SIMPLE MODE”, press the reset button (take off the thermostat face-
plate and press the reset button located in the bottom right-hand corner). The
message “Touch for simple thermostat” will appear. Touch the screen
immediately
,
and it becomes a simplified non-programmable thermostat.
>>
“SIMPLE MODE” has the following temperature control modes:
>>
“SIMPLE MODE” has the following fan operation modes:
Please note that when entering "Simple Mode" all configurations and settings
are stored permenantly.
>>
To revert back to the Programmable XCI Thermostat, simply press the reset
button and touch the screen when the message “Touch for Programmable
Thermostat” appears.
0706-XCI Manual-TSZ-1:TSZ-1 6/20/07 3:54 PM Page 38