FOR EXAMPLE:
If the temperature of surroundings is 38 °C (100 °F)
and you want to keep 50% of the battery capacity
when the kit cuts o the power for the camera,
you should set the kit so that the power is cut o
when the battery voltage is 12.192 V. Set the battery
protection switch to the 12.2 V setting. Only 50%
of the battery capacity will be used on the car camera,
even if you leave the car parked for a long time.
If it is a 50Wh lead-acid battery, 50% of the capacity
will allow for approximately 100 hours of camera
recording.
There are 4 protection settings in the
Xblitz R4 Power.
You can switch between them according to your
needs:
1. For 12V batteries, the protective settings are:
11.8 V/12.0 V/12.2 V/12.4 V.
2. For 24V batteries, the protective settings are:
23.6 V/24.0 V/24.4 V/24.8 V.
The Xblitz R4 Power Kit automatically recognizes
the lead-acid battery and will protect it from
over-discharge.
The 12.2 V/24.4 V setting is recommended for most
users.