Specifications and Characteristics
Output Performance Specifications
Release 1.1
73
Analog Programming Interface
Interlock - Remote Shutdown
4-15 V signal or TTL-compatible output, selectable logic
.
User Supply Voltage
+ 15 V supply voltage source with approximately 100
Ω
impedance
1
.
Switching Frequency
Typical 31 kHz; 62 kHz output ripple
Rise Time
5 to 95% step in output voltage.
Programming Lines, Impedance
0-5 V
dc
range
0-10 V
dc
range
Approximately 3 MOhm
Approximately 3 MOhm
Readback Lines, Impedance
0-5 V
dc
range
0-10 V
dc
range
Approximately 400 Ohm
Approximately 400 Ohm
Isolation, all program and readback lines
•
non-isolated for standard configuration, referenced to
supply “negative” output.
•
600 Vdc with respect to chassis potential or negative
output with Isolated Programming (ISOL) Internal Interface
card (available as an optional configuration)
TTL input impedance
2kOhm (in series with one diode drop)
Maximum Supply Voltage
15 V
dc
Minimum Supply Voltage
4 V
dc
Maximum Supply Voltage
17.5 V
Minimum Supply Voltage
14 V
1. Isolated from power supply output and chassis to 600 V.
Load Condition
Time (Max)
No Load
100 ms
Full Load
100 ms
Summary of Contents for XPR 10-600
Page 2: ......
Page 3: ...Operating Manual for XPR 6000 Watt Series Programmable DC Power Supply...
Page 10: ...About This Manual viii Operating Manual for XPR Series Power Supply...
Page 14: ...Contents xii Operating Manual for XPR Series Power Supply...
Page 16: ...List of Tables xiv Operating Manual for XPR Series Power Supply...
Page 18: ...List of Figures xvi Operating Manual for XPR Series Power Supply...
Page 48: ...Installation Remote Sensing 46 Operating Manual for XPR Series Power Supply...
Page 60: ...Operation Alarms 58 Operating Manual for XPR Series Power Supply...
Page 79: ......