Specifications and Characteristics
Output Performance Specifications
Release 1.1
71
Output Performance Specifications
These specifications define the electrical performance specifications of the power
supply output. These specifications apply to both local and remote sense
configurations, except where noted. These specifications apply to all programming
sources, except where noted.
Rated Output Range
Efficiency
•
Typical 89% efficiency at nominal line voltage and ambient temperature.
•
Minimum 82% efficiency. Specific minimum efficiency limits are model
dependent.
Load Regulation
Line Regulation
Programming Range for Voltage and Current
OVP Programming Range
•
0–103% of maximum rated voltage
Typical Programming Resolution
Front Panel Voltage and Current Meters
Voltage
0–100%
Current
0–100%
Voltage
5 mV + 0.05% of Vmax
Current
20 mA + 0.1% of Imax
Voltage
0.01% of Vmax
Current
0.05% of Imax
Voltage and Current
From 0–103% of the rated maximum output
Front Panel or Control Resolution
Voltage
Current
0.02% of Vmax
0.02% of Imax
3.5-digit green numeric LED displays. For accuracy
see
Table A.1, on page 66
and
Table A.3, on page 68
.
Summary of Contents for XPR 10-600
Page 2: ......
Page 3: ...Operating Manual for XPR 6000 Watt Series Programmable DC Power Supply...
Page 10: ...About This Manual viii Operating Manual for XPR Series Power Supply...
Page 14: ...Contents xii Operating Manual for XPR Series Power Supply...
Page 16: ...List of Tables xiv Operating Manual for XPR Series Power Supply...
Page 18: ...List of Figures xvi Operating Manual for XPR Series Power Supply...
Page 48: ...Installation Remote Sensing 46 Operating Manual for XPR Series Power Supply...
Page 60: ...Operation Alarms 58 Operating Manual for XPR Series Power Supply...
Page 79: ......