Protection Features
54
XPLORE 120/12 Battery Charger Owner's Guide
Absorption voltage @ 77 °F (25 °C)
Flooded
GEL
AGM
LFP
14.4 ±0.1
14.2 ±0.1
14.3 ±0.1
14.6
Float voltage @ 77 °F (25 °C)
Flooded
GEL
AGM
LFP
13.5
13.8
13.4
13.4
Equalize mode current
10A
Equalize mode—maximum output
voltage
16 ±0.1 VDC
Off-state current draw
<5 mA DC
Voltage regulation
Uncompensated load voltage regulation
< 0.1 VDC drop from 0 Amps to rated
current output at charger output
terminals (adds in series with
recommended 3% limit for user's battery
cable voltage drop).
Protection Features
XPLORE 120/12 Battery
Charger
Over-voltage limits
The XPLORE Charger will stop charging
if the output voltage is above
16.6 ±0.5 VDC
Output current limit
120A and 40A
Over-temperature
(measured internally)
Shutdown at 149 ±9 °F (65 ±5 °C)
Restart at 140 ±9 °F (60 ±5 °C)
Battery over-temperature protection
Charger shuts down if battery
temperature above 158 °F (70 °C) is
sensed by the optional battery
temperature sensor (BTS).
Battery under-temperature
protection
Charger shuts down if battery
temperature below –13 °F (–25 °C) is
sensed by the battery temperature
sensor (BTS).
Summary of Contents for XPLORE 120/12
Page 1: ...XPLORE 120 12 Battery Charger Owner s Guide Model XPLORE 120 12 Battery Charger 819 0120 12...
Page 16: ...This page is intentionally left blank 2...
Page 22: ...This page is intentionally left blank 2...
Page 42: ...This page is intentionally left blank 2...
Page 56: ...This page is intentionally left blank 2...
Page 68: ...975 1038 01 01 Rev A 30996 http www xantrex com 1 800 670 0707 1 408 987 6030 Printed in...