Introduction 

The XPH 35-4D and XPH 35-4Tv provide high levels of power (up to 305 watts) in a compact and 
attractive case style. 
High resolution controls allow precise setting of voltage and current levels which are indicated on 
accurate and legible digital meters. 
Excellent line and load regulation are matched by low noise and good transient response. High 
power efficiency ensures that the unit remains cool without any fan noise. 
The XPH 35-4D has two independent and isolated outputs each with a 0 to 35V, 0 to 4A 
capability. The outputs operate in constant voltage or constant current mode with automatic cross-
over and mode indication. Each output has its own on-off switch. Where higher voltages or 
currents are required the outputs can be wired in either series or parallel to provide voltages up to 
70 volts or currents up to 8 Amps. 
The XPH 35-4T has, in addition, an Auxiliary ‘logic voltage’ output with a 5A current capability. To 
reflect the increasing usage of low-voltage logic devices, this output can be preset between  
1.5 volts and 5 volts via a front panel control. 
The total power capability is 280 watts for the dual supply and 305 watts for the triple. 
The XPH series incorporates separate digital voltage and current meters on each main output. 
The meters use bright 14mm (0·56”) LED displays and have an update rate of 4 per second 
providing near instantaneous response. Simultaneous metering of voltage and current provides 
accurate information “at a glance” and avoids any possibility of misinterpretation. When an output 
switch is set to “off”, the current limit setting is displayed enabling conditions to be set before the 
load is connected.  With the right-hand main output off, the right-hand meters can be used to 
momentarily display the preset Auxiliary voltage and current limit. 
The XPH series has been designed to meet the stringent requirements of relevant IEC standards 
for safety and EMC, including harmonics emissions. All outputs are intrinsically short circuit proof, 
and are protected against external voltages and reverse currents. 

Specification 

 MAIN OUTPUTS 

Voltage Range: 

0V to 35V minimum. 

Current Range: 

0A to 4A minimum. 

Output Voltage Setting: 

By coarse and fine controls. 

Output Current Setting: 

By single logarithmic control. 

Operating Mode: 

Constant voltage or constant current with automatic cross-over. 

Output Switch: 

Electronic. Preset voltage and current displayed when off. 

Output Terminals: 

Universal 4mm safety binding posts on 19mm (0·75”) pitch. 

Output Impedance: 

Typically <5m

 in constant voltage mode.  

Typically >50k

 in constant current mode. 

Output Protection: 

Output will withstand up to 40V forward voltage.  
Reverse protection by diode clamp for reverse currents up to 3A. 

Load Regulation: 

<0·01% of maximum output for 90% load change. 

Line Regulation: 

<0·01% of maximum output for 10% line change. 

Ripple & Noise 
(20MHz bandwidth): 

Typically <2mVrms, <10mVpk-pk (CV mode). 

  

 

Summary of Contents for XPH 35-4D

Page 1: ...www programmablepower com XPH 35 4D XPH 35 4T XPH Series Dual and Triple Output 35V 4A DC Power Supply Operating Manual...

Page 2: ...eir respective owners and are used herein for identification purposes only Notice of Copyright Xantrex International All rights reserved Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING XANTREX TEC...

Page 3: ...ralit s 16 Maintenance 17 Bedienungsanleitung auf Deutsch Sicherheit 18 Installation 19 Anschl sse 19 Betrieb Hauptausg nge 20 Betrieb Hilfsausgang 21 Betrieb Allgemein 21 Wartung 22 Istruzioni in Ita...

Page 4: ...econd providing near instantaneous response Simultaneous metering of voltage and current provides accurate information at a glance and avoids any possibility of misinterpretation When an output switch...

Page 5: ...rotection Output will withstand up to 7V forward voltage Diode clamp reverse protection for currents up to 3A Load Regulation 0 5 for 90 load change Line Regulation 0 1 for 10 line voltage change Ripp...

Page 6: ...ormance A According to EN61326 the definitions of performance criteria are Performance criterion A During test normal performance within the specification limits Performance criterion B During test te...

Page 7: ...hibited The protective action must not be negated by the use of an extension cord without a protective conductor When the instrument is connected to its supply terminals may be live and opening the co...

Page 8: ...ows The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol shown above or coloured green or green and y...

Page 9: ...setting would flow the power supply will automatically move into constant current operation The current output is adjusted by the CURRENT control and the VOLTAGE controls set the maximum voltage that...

Page 10: ...and earth ground is 300VDC the maximum permissible voltage between either terminal of one output and any terminal of another output on the same supply is also 300VDC WARNING Such voltages are exceedin...

Page 11: ...a skilled person who is aware of the hazard involved Remove the 6 side screws and the front handle screw to release the top cover Component adjustment references are given as Channel A Channel B e g V...

Page 12: ...act reading Connect load set current control to maximum and adjust load for 4A output current Note that the DMM should be connected at the back of the output terminals closest to the internal sense co...

Page 13: ...he supply has developed a fault in such circumstances the instrument will need to be returned to the manufacturer for service Make sure that only fuses of the required rated current and specified type...

Page 14: ...de protection car ceci annulerait sa capacit de protection Lorsque l instrument est reli au secteur il est possible que les bornes soient sous tension et par suite l ouverture des couvercles ou la d p...

Page 15: ...couleur d identification des bornes de la fiche et par suite il est recommand de proc der de la mani re suivante Relier le fil vert et jaune la borne de la fiche d sign e par la lettre E ou par le sym...

Page 16: ...n de sortie r gl e l alimentation passera automatiquement en mode de fonctionnement de courant constant La commande CURRENT ajuste le courant de sortie et les commandes VOLTAGE r glent la tension maxi...

Page 17: ...n maximale admissible entre une borne et la terre est de 300V c c la tension maximale admissible entre la borne d une sortie et la borne d une autre sortie de la m me alimentation est galement de 300V...

Page 18: ...c est le cas il faudra renvoyer l instrument chez le constructeur en vue de r parations Uniquement remplacer les fusibles par des fusibles d intensit nominale requise et de type sp cifi Il est interd...

Page 19: ...wirkung darf durch Verwendung eines Verl ngerungskabels ohne Schutzleiter nicht aufgehoben werden Ist das Ger t an die elektrische Versorgung angeschlossen so k nnen die Klemmen unter Spannung stehen...

Page 20: ...n Ihres Steckers bereinstimmen ist wie folgt vorzugehen Die gr n gelbfarbene Ader ist an die mit E oder mit dem oben abgebildeten Schutzleitersymbol markierte oder gr n bzw Gr n gelbfarbene Steckerkle...

Page 21: ...w rde der gr er w re als die eingestellte Strombegrenzung so schaltet die Stromversorgung automatisch auf konstanten Strombetrieb Der Stromausgang wird mit dem Knopf CURRENT eingestellt und die maxim...

Page 22: ...iden Klemmen eines Ausgangs und einer beliebigen Klemme eines anderen Ausgangs desselben Ger ts betr gt ebenfalls 300V Gleichspannung WARNUNG Spannungen in dieser Gr enordnung sind beraus gef hrlich B...

Page 23: ...egt In einem solchen Falle ist es erforderlich da das Ger t vom Hersteller repariert wird Achten Sie darauf da nur Sicherungen der vorgeschriebenen Stromst rke und des angegebenen Typs als Ersatzsiche...

Page 24: ...otettiva non deve essere negata dall uso di una prolunga priva conduttore di protezione Quando lo strumento collegato all alimentazione alcuni morsetti sono sotto tensione e l apertura dei coperchi o...

Page 25: ...o deve essere collegato al morsetto della spina contrassegnato con la lettera E oppure con il simbolo di sicurezza che rappresenta la terra o di colore verde o verde giallo Il filo blu deve essere col...

Page 26: ...cita impostata scorra una corrente superiore al limite impostato l alimentazione assumer automaticamente un funzionamento a corrente costante L uscita di corrente viene regolata con il comando CURRENT...

Page 27: ...morsetto di un altra uscita sulla stessa alimentazione anch essa 300Vc c ATTENZIONE Queste tensioni sono estremamente pericolose e bisogna assicurarsi nel modo pi assoluto di coprire i morsetti d usc...

Page 28: ...tanze lo strumento deve essere restituito al produttore per la riparazione Per la sostituzione accertarsi che vengano usati fusibili del tipo e della corrente nominale specificati proibito usare fusib...

Page 29: ...n a tierra No debe utilizarse con un cable de tension sin tierra Mientras el instrumento est conectado es posible que queden sin protecci n elementos bajo tensi n y la obertura de tapas o el retiro d...

Page 30: ...dos en los bornes de su enchufe proceder como sigue El cable de color verde y amarillo debe conectarse al borne del enchufe marcado con la letra E o con el s mbolo de seguridad de tierra mostrado arri...

Page 31: ...rica cambiar autom ticamente a operaci n con corriente constante Se ajusta la salida de corriente con el control CURRENT y los controles VOLTAGE ajustan la tensi n m xima que se puede generar Se ilumi...

Page 32: ...nsi n m xima admisible entre cualquier borne y la tierra f sica es de 300 VCC la tensi n m xima admisible entre uno u otro de los bornes de una salida y cualquier borne de otra salida del mismo sumini...

Page 33: ...n el ctrica en tales circunstancias ser necesario devolver el instrumento al fabricante para una revisi n Asegurar que se empleen s lo fusibles de la clasificaci n y del tipo especificado para todo r...

Page 34: ...and return shipment to the customer via a Xantrex selected non expedited surface freight within the contiguous United States and Canada Alaska and Hawaii are excluded Contact Xantrex Customer Service...

Page 35: ...HANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT REQUIRED UNDER APPLICABLE LAW TO APPLY TO THE PRODUCT SHALL BE LIMITED IN DURATION TO THE PERIOD STIPULATED UNDER THIS LIMITED WARRANTY IN...

Page 36: ...reached during work hours A brief description of the problem 3 Ship the unit prepaid to the address provided by your Xantrex customer service representative If you are returning a product from outside...

Page 37: ...Brown Deer Road San Diego CA USA 92121 858 450 0085 Tel 858 678 4481 Fax 800 733 5427 Toll Free North America sales programmablepower com service programmablepower com www programmablepower com 975 01...

Reviews: