![Xantrex XKW 600-1.7 Operating Manual Download Page 31](http://html1.mh-extra.com/html/xantrex/xkw-600-1-7/xkw-600-1-7_operating-manual_3375359031.webp)
Installation
AC Input Power
Release 2.2
29
100-130Vac 20A Input
To convert the unit for use with a 100-130Vac 20 A
input, perform the following steps:
1. Ensure that the unit is switched off and disconnected from any power source.
2. Remove the Phillips head screws which secure the cover and then remove the
cover from the unit.
3. Remove the 230Vac voltage selector jumper located at the front center of the
PCB from its mating header (designated P1 on the PCB) and install the attached
115Vac jumper in its place.
4. Reinstall the cover and replace the screws.
5. Use the adhesive backed 115Vac 20A label supplied with the unit to cover the
230Vac 10A input specification above the rear panel AC connector.
6. Install a 130Vac 25A plug and cord ensuring that the neutral (white) wire and
line (black) wire are connected in the correct positions and that the safety ground
wire is connected to the ground screw.
Input Line
Impedance
The maximum input line impedance for operation at full rated output is 1 ohm.
Higher source impedances can be tolerated by raising the input line voltage or by
reducing the output voltage and/or current.