![Xantrex XKW 600-1.7 Operating Manual Download Page 16](http://html1.mh-extra.com/html/xantrex/xkw-600-1-7/xkw-600-1-7_operating-manual_3375359016.webp)
Features and Specifications
Rear Panel Connectors and Switch
14
Operating Manual for XKW 1kW Series Power Supply
Rear Panel Connectors and Switch
The input AC power, output DC power, as well as the remote program sense and
monitor connector are located on the rear panel. The program and monitor function
selector switch (SW1) is located internally on the main PCB. See
Figure 1.2, on page
15
for locations. Refer to
Section 2, “Installation”
for detail on procedures for
connections and settings.
Controls, Connectors, and Indicators
Please refer to
Figure 1.1, “Power Supply Front Panel” on page 13
for front panel
controls and indicators,
Figure 1.2, “Power Supply Rear Panel” on page 15
for rear
panel connectors and switch details, and to
Figure 1.3, “J3 Program, Sense, and
Monitor Connector Description” on page 16
for a description of the J3 Program,
Sense, and Monitor Connector.
Note: J3 pins 1, 2, and 14 form an isolated control function and may be biased
relative to the supply output
!
CAUTION
All remote programming input and monitoring lines are internally referenced to the
supply’s negative output. Do not reference remote programming or monitor lines to
the supply’s positive output. J3 pin 6 (ground) is directly connected to the supply’s
negative output. Do not connect this pin to the positive output or to the chassis.