Remote Communication & Monitoring
4-16
TM-DIOP-01XN-01
Table 4-5
Setup Page of Web Interface
Object
Description
Monitor Page
Refresh Rate
The rate at which to automatically refresh the monitor
page
(The Refresh Data link on the “Monitor Page” should be
selected for the new refresh rate to take effect.)
Active IP
Inverter’s active IP address
Default IP
Set this value to a static IP if desired or set it to 0.0.0.0
to use a DHCP server.
Gateway IP
Address for network gateway
Sub-Net Mask
Identifies which portion of IP address is the network ID
and which portion is the host ID
Domain Name
Server #1
IP address to common name translator #1
Domain Name
Server #2
IP address to common name translator #2
SMTP (email) Server Address of network email server
Email Alert Address
Email address used to send alert messages
Web Password
Text to change to a new password (4–10 characters
long)
Leave empty to disable password
Password Confirm
Confirmation of new password
Submit
Updates the Ethernet interface card with the above
configuration
Manage Link
Link to Setup Page
Monitor Link
Link to Monitor Page
Setup Link
Link to same page