type, and the switch should be set to the position marked "FLOOD-
ED". If your battery is sealed, and has no caps, set the switch
to "GEL".
4)
Set the "BATTERY TEMPERATURE" selector switch for the
temperature of your battery, using the following chart:
5)
Apply AC power to the Truecharge 20i/40i, and the yellow
"CHARGING" indicator will light. The green "READY" indicator
on the Truecharge 20i/40i will light when the battery is fully
charged, and ready for use.
Operating Instructions -
Equalization Charge Cycle
If you are using a flooded lead acid battery, an occasional equalization
charge may be recommended by the manufacturer. Equalization
restores the battery's maximum capacity and reduces the risk of
premature battery failure.
Precautions:
Caution:
Equalization should only be performed on a flooded
lead acid battery. Do not equalize a battery unless there are
provisions to add water to the battery. Never equalize a battery
more than two times per month, and always check battery
fluid level before AND after equalization. Fill only with
DISTILLED water.
Battery Temperature (ºC)
Switch Setting
below 10ºC
"COLD"
10ºC - 27ºC
"WARM"
above 27ºC
"HOT"
7