Operation
Command Summary
Release 1.2
37
Command Summary
Use these commands to control the operation of the supply. They are listed here in
order of function such as PROGRAMMING, QUERY, CALIBRATION, and
STATUS commands. See “Command Reference” on page 40 for more detailed
information about each command and its use.
Table 3.3
Programming Commands
Command
Description
AUXA
Selects the state of the AUXA output signal on the J21-7 connector.
AUXB
Selects the state of the AUXB output signal on the J21-8 connector.
CLR
Initializes the power supply to its Power ON (PON) state.
DLY
Sets a programmable time delay which is executed by the supply
before reporting fault conditions after a new output voltage or current is
specified.
GTL
Sends the supply to local mode.
FOLD
Sets foldback mode for the supply.
HOLD
Enables or disables voltage/current setting hold mode for the supply.
IMAX
Sets an upper soft limit on the programmed output current for the
supply.
ISET
Sets the output current of the supply in amps (default) or in milliamps.
LLO
Local Lockout. Disables the front panel LOCAL button.
OUT
Enables or disables voltage/current output for the supply.
OVSET
Sets the over voltage protection trip point for the supply in volts
(default) or in millivolts.
RST
Resets the supply to the present voltage and current settings if the
output is disabled by OVP or foldback protection.
TRG
Implements programmed voltage and current settings which had been
in hold mode.
VMAX
Sets an upper soft limit on the supply’s programmed output voltage.
VSET
Sets the output voltage of the power supply in volts (default) or in
millivolts.