background image

6

66

6

(inverting) the battery bank. The lower portion of the 

Amps DC

  scale also

displays the four 

Error

 conditions. In the upper right portion of the RC6 are

two lights marked 

Bulk Charge

 and 

Float Charge

.  These lights indicate

the stage the battery charger is in. When the inverter is inverting, they are

not lit.

Let’s take a more detailed look at each of the items pointed out in the picture above.

Power On/Off Switch and LED Indicator

The power on/off switch on the lower front right of the remote is a momentary type

switch and alternately turns the inverter on or off when pressed. The green light in the

middle of it will be lit steadily when the inverter is working, and if the inverter is in the

load search sense mode it will blink on and off rapidly. In charger mode the light will

blink slow green.

Battery Voltage Bar Graph

This bar graph contains a light that will move up and down the bar as the battery

voltage changes. The corresponding battery voltage is read to the left of the light. Red

lights mean out of tolerance, yellow lights marginally within tolerances, and green lights

show that everything is in a normal operating range. It is perfectly normal for battery

voltage to drop a bit when operating heavy loads. The inverter constantly monitors the

battery bank and will not allow it to be over discharged or over charged.

Note:

 A completely dead battery will read about 11.6 volts or less in an

“at rest” condition. “At rest” means the battery has been sitting dormant

for several hours with no load on it, and is not being recharged. When

the battery drops below a certain pre-set point, the inverter will shut

down, and if AC power is available to the inverter, it will recharge the

batteries.

!

 

Voltage

 is

electrical

pressure. It is

equivalent to

water pressure in

a hose.

!

 

Current 

or

Amps

 is the

volume of

electrical flow,

just like gallons

per hour through

a garden hose.

Battery current
(into or out of battery bank)

Charge
lights

Battery
voltage

Error legend

On/Off button

Summary of Contents for RC6

Page 1: ...User s and Installation Guide RC6 Xantrex RC6 Remote On Off Switch and Monitor ...

Page 2: ...1 1 1 1 RC6 REMOTE ON OFF SWITCH AND MONITOR ...

Page 3: ...THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION b ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE WHETHER DIRECT INDIRECT CONSEQUENTIAL OR INCIDENTAL WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RISK Date and Revision October 2002 Revision 1 ...

Page 4: ...r On Off Switch and LED Indicator 6 Battery Voltage Bar Graph 6 Amps DC Bar Graph 7 Error Conditions 7 Bulk Charge and Float Charge Lights 8 Installation 10 Installation Procedure 10 Warranty 11 Disclaimer 13 Product 13 Exclusions 13 Warning Limitations On Use 13 Return Material Authorization Policy 14 Return Procedure 14 ...

Page 5: ...4 4 4 4 ...

Page 6: ...ur guide to what the inverter is doing Let s look at some of the features of the Xantrex RC6 Remote Control Reading the RC6 Remote Control The RC6 remote control is capable of turning the inverter on and off as well as showing the following Battery Bank Voltage Current flowing into or out of the battery bank during charging or inverting Error conditions the inverter may encounter High Battery Over...

Page 7: ...wn the bar as the battery voltage changes The corresponding battery voltage is read to the left of the light Red lights mean out of tolerance yellow lights marginally within tolerances and green lights show that everything is in a normal operating range It is perfectly normal for battery voltage to drop a bit when operating heavy loads The inverter constantly monitors the battery bank and will not...

Page 8: ... low battery condition if you have small batteries or high usage If the inverter charger encounters a situation it can t handle then it will shut down and protect itself the battery bank and your appliances The following four situations are monitored protected against and displayed on the RC6 High Battery The battery voltage has risen above 15 0 volts DC and the inverter will shut down until accep...

Page 9: ... loads will then resume operation from the pass through power thus running from the external AC source The bottom four lights of the Amps DC meter show the error condition represented by the adjacent Error box legend During an error condition the appropriate error light will flash The inverter will attempt to automatically restart itself every few seconds until the condition is remedied Bulk Charg...

Page 10: ...e RC6 will remain on solid During the Absorption Charge stage the Bulk Charge light will blink slowly This stage tops off the battery The float or maintenance charge stage trickle charges the battery while keeping it in fully charged ready to go state This stage is indicated on the RC6 by the Float Charge light slowly flashing During the charge process the battery voltage and current being fed int...

Page 11: ...rill four 1 16 inch holes for mounting screws not included The cutout for the RC6 should be 4 1 8 inches wide by 4 3 16 inches high by at least 15 16 of an inch deep Next plug the cable into the connector on the back of the RC6 then to the inverter It is never recommended to route any low voltage DC wiring such as the RC6 cable in the same conduit or bundle with wiring that carries AC power Induce...

Page 12: ...ed by this Limited Warranty Xantrex will at its option use new and or reconditioned parts in performing warranty repair and building replacement products Xantrex reserves the right to use parts or products of original or improved design in the repair or replacement If Xantrex repairs or replaces a product its warranty continues for the remaining portion of the original Warranty Period or 90 days f...

Page 13: ...original equipment manufacturer OEM status or The dated invoice or purchase receipt showing the product exchanged under warranty What does this warranty not cover This Limited Warranty does not cover normal wear and tear of the product or costs related to the removal installation or troubleshooting of the customer s electrical systems This warranty does not apply to and Xantrex will not be respons...

Page 14: ...ESTRICTION ANY ECONOMIC LOSSES OF ANY KIND ANY LOSS OR DAMAGE TO PROPERTY ANY PERSONAL INJURY ANY DAMAGE OR INJURY ARISING FROM OR AS A RESULT OF MISUSE OR ABUSE OR THE INCORRECT INSTALLATION INTEGRATION OR OPERATION OF THE PRODUCT Exclusions If this product is a consumer product federal law does not allow an exclusion of implied warranties To the extent you are entitled to implied warranties unde...

Page 15: ...rials Please ensure that your product is shipped fully insured in the original packaging or equivalent This warranty will not apply where the product is damaged due to improper packaging 2 Include the following The RMA number supplied by Xantrex Technology Inc clearly marked on the outside of the box A return address where the unit can be shipped Post office boxes are not acceptable A contact tele...

Page 16: ...Xantrex Technology Inc Toll free 1 800 670 0707 Direct 1 604 422 2777 Fax 1 604 420 2145 CustomerService xantrex com www xantrex com 975 0051 01 01 Rev 1 Printed in the U S A ...

Reviews: