M9B-HFS INTERFACE
APPENDIX A
Release 1.0 (97/10)
A-1
A.
SPECIFICATIONS
A.1 XFR 1200 Watt Series Supplies with M9B-HFS Interface
Installed
All specifications are subject to change without notice. Specifications are warranted from 25°C
±
5°C unless
otherwise specified.
Table A-1 Electrical Specifications for XFR 1200 Watt Series
7.5 Volt to 60 Volt Models
Models
7.5-140
12-100
20-60
40-30
60-20
Program Resolution
Voltage
Current
OVP
0.2mV
4.8mA
0.2mV
0.3mV
3.4mA
0.3mV
0.4mV
2.1mA
0.4mV
0.8mV
1.0mA
0.8mV
1.3mV
0.7mA
1.3mV
Program Accuracy
1
Voltage
Current
OVP
10mV
±0.12%
500mA
0.1%
80mV
75mV
±0.12%
250mA
0.1%
200mV
75mV
±0.2%
165mA
0.15%
330mV
75mV
±0.3%
140mA
0.15%
400mV
150mV
±0.25%
120mA
0.1%
600mV
Readback Resolution
Voltage
Current
0.2mV
4.8mA
0.3mV
3.4mA
0.4mV
2.1mA
0.8mV
1.0mA
1.3mV
0.7mA
Readback Accuracy
1
Voltage
Current
30mV
±0.12%
500mA
0.1%
75mV
±0.12%
250mA
0.1%
75mV
±0.2%
165mA
0.15%
75mV
±0.3%
140mA
0.15%
150mV
±0.25%
120mA
0.1%
Table A-2 Electrical Specifications for XFR 1200 Watt Series
100 Volt to 600 Volt Models
Models
100-12
150-8
300-4
600-2
Program Resolution
Voltage
Current
OVP
2.1mV
0.4mA
2.1mV
3.2mV
0.6mA
3.2mV
6.3mV
0.1mA
6.3mV
12.6mV
0.1mA
12.6mV
Program Accuracy
1
Voltage
Current
OVP
150mV
±0.35%
80mA
0.1%
1.0V
225mV
±0.35%
80mA
0.1%
3.0V
225mV
±0.35%
80mA
0.1%
3.0V
300mV
±0.35%
75mA
0.1%
6V
Readback Resolution
Voltage
Current
2.1mV
0.4mA
3.2mV
0.6mA
6.3mV
0.1mA
12.6mV
0.1mA
Readback Accuracy
1
Voltage
Current
150mV
±0.35%
80mA
0.1%
225mV
±0.35%
80mA
0.1%
225mV
±0.35%
80mA
0.1%
300mV
±0.35%
75mA
0.1%
1
Apply accuracy specifications according to the following voltage program accuracy example:
Set a model XFR 20-60 power supply to ten volts.