INSPECTION AND CONFIGURATION
M9B-HFS INTERFACE
2-2
Release 1.0 (97/10)
2.2 M9B-HFS Setup Procedure
To use this product, you must have the following equipment:
•
Two fiber optic cables, or one duplex fiber optic cable (for receiving and transmitting)
•
Computer with a fiber optic serial interface
•
Computer-based communications software package
•
1200W or 2800W variable DC output power supply with M9B-HFS interface installed
You can configure the M9B-HFS option for operation in four simple steps. Follow all steps in Table 2.2-1 M9B-
HFS Setup Procedure in the order provided.
Table 2.2-1 M9B-HFS Setup Procedure
Step #
Procedure
References
1
Set the back panel S1
Communication Switch for operation.
See Section 2.3 S1 Switch Communication
Settings
for information on setting the Baud Rate and Flow
control for the interface.
2
Install the fiber optic lines between
the computer and the interface.
See Section 2.4 Connecting the Fiber Optic Line for
information on the fiber optic connector.
3
Power ON the power supply.
See Section 2.5 Power ON Conditions for information
on power supply default settings and remote
operation.
4
Set the command protocol for the
computer.
See Section 2.6 Computer Settings. The computer
and the interface must share the same serial
settings to ensure proper communication.
For additional interface functions, see Section 2.8 J7 User Signal Connector and Section 2.7 Internal Jumper
Selections .