Basic Installation Procedures
28
Freedom XC PRO Owner's Guide
WARNING
ELECTRIC SHOCK HAZARD
Use a screwdriver to loosen the captive nut panel screw.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
Figure 8 Loosening the captive nut panel screw
1
1
Captive nut panel screw
4. Strip a single AC input wire, as appropriate. Strip 10 mm off
the ends of each of the three the wires (tin the exposed
copper wire with lead-free solder using a soldering iron).
5. Install a ½" (or ¾") strain relief clamp on the AC input hole.
6. Route the wires through the strain relief clamp (not shown in
the figure).
Figure 9 Routing the wires
N
L
G
N
L
G
N
L
G
2
1
3
4
5
1
step 8a
2
step 8b
3
step 8c
4
10mm
5
to circuit breaker
NOTE
: AC input hole - install a strain relief clamp (not shown).
7. Locate the Neutral, Ground and Line terminals on the AC
input terminal labeled as
N
,
G
, and
L
respectively.