Operating Limits
975-1175-01-01
57
Operating Limits
These are the operating limits of the Freedom XC:
n
n
n
n
n
Power Output
The Freedom XC can deliver up to 1800 W
1
of continuous utility
grade sine wave AC power. The wattage rating applies to resistive
loads such as incandescent lights.
Input Voltage
The allowable Freedom XC input battery voltage ranges are
shown in the following table:
Operating
Condition
Battery
Voltage
Comment
Full
Operating
Range
LBCO–18.0 V
Assuming the battery is full, the inverter/charger
will operate until battery voltage goes past below
LBCO
b
and LBCO Shutdown delay timer
c
.
Low Voltage
Recovery
< LBCO+0.2 V
Inverter is able to recover and continue to
operate.
Table 12 Input battery voltage range
1
As the temperature rises, it will gradually reduce its continuous power output from 1800 W at 40°C
ambient to 1500 W before the over-temperature shutdown occurs at 60°C ambient. See
b
To set LBCO, see
Adjusting Feature Settings in Configuration Mode on page 43
c
To set LBCO Shutdown Delay Timer, see