A–4
975-0395-01-01
This guide for use by qualified installers only
Environmental Specifications
System Specifications
Physical Specifications
Regulatory Approvals
Ambient Temperature:
Operating Temperature Range
Storage Temperature Range
0–40 ºC
-20–60 ºC, with output derated above 25 °C
-40–70 ºC
Humidity: Operation/Storage
5–95% RH, non-condensing
Transfer relay rating
30A, 2.0hp
Transfer time
<30ms
Transfer on bad voltage
90–100V for low AC and
130–140 for high AC
Cooling
Fan, activated by any of the following:
•
High internal temperature
•
High AC output power
Unit Dimensions and Weight
Freedom HF 1000
Freedom HF 1800
Length
15.5” (393mm)
18.0” (457mm)
Width
9.5” (241mm)
9.5” (241mm)
Height
4.2” (106mm)
4.2” (106mm)
Weight
10 lbs (4.5 kg)
12.8 lbs (5.8 kg)
ETL approved to CSA 107.1, UL458, and UL458 Marine Supplement (drip shield
with product number 808-9531 required).
FreedomHF_IC_A-Specifications.fm Page 4 Monday, December 24, 2007 9:48 AM