This guide for use by qualified installers only
AC Output:
The circuit breaker or fuse must be rated at no more than
the rating of the input breaker in the installation and must be
approved for use on 120 Vac branch circuits. The wire used between
the
Freedom HF
and the AC output breaker must be of adequate size
to match the AC input circuit breaker’s rating. The wiring from each
AC output breaker to each of the loads must be adequately sized to
carry the current rating of the individual AC output breaker.
Disconnect Devices:
Each system requires a method of
disconnecting the AC circuits. If the over-current protection devices
are circuit breakers, they will also serve as the disconnects. If fuses
are used, separate AC disconnect switches will be needed ahead of
the fuses. These will have to be a branch circuit rated for 120 Vac and
have an appropriate current rating.
AC Distribution
Panels
Most systems incorporate distribution centers both ahead of the
Freedom
HF
(the AC source panel) and between the
Freedom HF
and the loads (the
AC load panel). An AC source panel includes a main circuit breaker,
which serves as over-current protection and as a disconnect for the AC
shore power supply line. Additional circuit breakers serve individual
circuits, one of which serves the
Freedom HF
. The AC load panel can
incorporate an AC output circuit breaker and breakers for individual load
circuits.
AC Cabling
AC cabling includes all the wires and connectors between the AC source
and the
Freedom HF
, as well as all cabling between the
Freedom HF
and
the AC output panels, circuit breakers, and loads. The type and size of the
wiring varies with the installation and load. For example, in high
vibration environments, such as marine or RV applications, wire nuts may
not be acceptable, so crimp splices would be required. In other
applications, flexible multiple-strand wire may be required. Installation
codes usually specify solid or stranded, overall size of the conductors, and
type and temperature rating of the insulation around the wire.
CAUTION: Equipment damage
Do not connect the output of the
Freedom HF
to what is known as a “multi-wire
branch circuit”. These are four-wire circuits consisting of a ground, neutral, and
two lines that are 180 degrees out of phase with each other (from a standard 120/
240V “split phase” circuit). These circuits are commonly used in kitchens to
power “split receptacles” where the top and bottom halves of a duplex receptacle
are connected to different lines.
FreedomHF_IC_01-Installation.fm Page 8 Monday, December 24, 2007 9:47 AM
Summary of Contents for FREEDOM HF 1000
Page 2: ...Freedom HF Install Guide book Page ii Friday December 21 2007 9 57 PM...
Page 56: ...2 6 FreedomHF_IC_02 Configuration fm Page 6 Monday December 24 2007 9 48 AM...
Page 64: ...A 8 FreedomHF_IC_A Specifications fm Page 8 Monday December 24 2007 9 48 AM...
Page 68: ...B 4 Freedom HF Install Guide book Page 4 Friday December 21 2007 9 57 PM...
Page 69: ...Freedom HF Install Guide book Page 5 Friday December 21 2007 9 57 PM...