![Xantrex Fleet Power FP 3000-12 Owner'S Manual Download Page 9](http://html.mh-extra.com/html/xantrex/fleet-power-fp-3000-12/fleet-power-fp-3000-12_owners-manual_881387009.webp)
9
OPERATION
• When the LED is blinking slowly (once
per second), an over-current condition or a
short circuit has occured. The system has
shut OFF and will not automatically restart.
Correct the fault condition and manually restart
the system.
LOW BATTERY & OVERTEMP/OVERLOAD
- Red LEDs
• When both LEDs are blinking, an AC
backfeed has been detected. A backfeed occurs
when AC power from an external source is
connected to the output of the inverter. Inspect
wiring for a possible input/output wiring error.
This condition will damage the unit and must
be corrected before further operation.
TSC (Temperature Sensitive Charging)
This provides for the connection of a sensor to
measure battery temperature for compensated
charging. If no sensor is connected the charge
voltage levels are set to defaults based on
battery type.
OPTIONAL REMOTES
If using a remote, refer to the installation
instructions included with the remote.
Note: When a Remote Control Panel is installed,
the jumper included in the parts plastic bag is
not
used in the Auxiliary Switch Port (AUX
SWITCH) on the front panel of the inverter/
charger. See page 23 for more details.
Remote
TSC
Overtemp
Low
Battery
Auxiliary Port
Summary of Contents for Fleet Power FP 3000-12
Page 1: ...Owner s Manual Xantrex Fleet Power TM 3000 12 Inverter Charger FP 3000 12 ...
Page 32: ...32 page intentionally blank ...
Page 36: ...36 page intentionally blank ...
Page 42: ...42 page intentionally blank ...
Page 47: ...47 ...