28
COMPRESSION / RING TERMINAL
INSTALLATION
Improper stack up of hardware will cause
excessive heat and fuse failure. Stack up
as shown.
WARNING
Battery Cable Fusing
A fuse is required by the NEC to protect the
battery and cables. A UL Listed DC rated slow
blow fuse must be installed in the positive (+)
battery cable, within 18 inches of the battery.
Recommended Fuse:
UL Listed Class T
JLLN
with a DC Rating. This fuse with fuse
holder is available from your dealer.
For the FP3000-12
350 Amp Fuse & Holder PN# 84-4159-00
350 Amp Fuse Only PN# 84-4152-00
RING / RING TERMINAL
FUSE HOLDER
FUSE
BATTERY
CABLE
INVERTER
CABLE
FLAT WASHER
LOCK WASHER
NUT
FUSE HOLDER
FUSE
BATTERY
CABLE
INVERTER
CABLE
FLAT WASHER
LOCK WASHER
NUT
EXPLODED VIEWS
OF FUSE ASSEMBLY
+ (red)
+
_
HARDWARE STACK-UP OPTIONS