Advanced Section
M370046-06
2-29
Network Topology 2: ENET and RS-485 Bus
Up to 30 units may be connected to the RS-485 bus. The first unit
connects to the controller via ENET, and the other units are connected
with the RS-485 bus.
Figure 2-35 shows the system of an XTR unit with the ENET option and
several XTR units connected via the RS-485 bus. Each power supply
must have its own address, defined from the front panel. Only one IP
address is required for your network (excluding computers) and only one
controlling program is required (one per XTR with ENET option as noted
in “Network Topology 1: Simple LAN” on page 2–25).
Figure 2-35
ENET and RS-485 Bus
IN
OUT
IN
OUT
IN
OUT
ENET
Local Computer
RS-485
RS-485
Power Supply #1
Power Supply #30
Power Supply #2