Troubleshooting

WARNING

ELECTRICAL SHOCK HAZARD

If the in-line fuse on the 10AWG positive (+) battery cable blows, replace with a 30A/32V green ATC
blade fuse.

Failure to follow these instructions can result in death, serious injury, or equipment
damage

.

NOTE

: To obtain service go to

Contact Information on page 1

.

Problem

Possible Cause

Solution

Battery does not get charged
even when sunlight is
present.

Solar panel is partially shaded
or there is insufficient sunlight.

Move the vehicle or vessel so the whole
solar panel is exposed to direct sunlight.

Loose or no DC cable
connections.

Connect DC cables to the battery and
solar panel and tighten terminal
connections.

Fuse is blown.

Replace the blown fuse with a 30A/32V
green ATC blade fuse.

Specifications

NOTE:

Specifications are subject to change without prior notice.

110W Solar Flex Panel

Part number

781-0110

Dimensions

39.6 × 26.9 × 0.12 inches
(1005 × 683× 3 mm)

Unit weight

5.5 lbs.(2.5 kg)

Cell Type

Monocrystalline PERC

Maximum power at STC*

110 W

Maximum power voltage

18.9 V

Maximum power current

5.83 A

Open circuit voltage

19.49 V

Short circuit current

5.95 A

Maximum system voltage

600 VDC

Safety

Class III PV Module

* Standard Test Conditions (STC): Irradiance: 1000W/m2, CellTemperature: 25°C, Air Mass: 1.5

10

975-1028-01-01 Rev A

January 2021

Summary of Contents for 781-0110

Page 1: ...energy to a battery during daylight hours The Xantrex Solar Flex Panel base package includes the following items n one Xantrex Solar Flex Panel n one Installation Guide n six 12 size 1 length hex dri...

Page 2: ...assemble the solar flex panel except where noted for connecting wiring and cabling See your warranty for instructions on obtaining service Attempting to service the solar flex panel yourself may resul...

Page 3: ...nce with all applicable installation codes and regulations n Disconnect all power sources n Disable and secure disconnect devices Failure to follow these instructions can result in death serious injur...

Page 4: ...ea that is readily accessible viewable and free from exposure to moisture c Plan the route and measure the lengths of cables needed to reach their connection points factoring in bends and slack d You...

Page 5: ...anel s backside and place the panel on the exact and intended location Alternatively install the solar panel on the roof using appropriate screws and washers to fasten the panel TIP 2 If using screwst...

Page 6: ...ute the PV cables through the roof entry point and connect the red pos and black neg PV cables to the charge controller See T3 d Connect the red pos and black neg battery cables to the charge controll...

Page 7: ...power point tracking 30A 12 24VDC 710 3024 01 b Solar panels can be configured in series parallel or a combination of both series and parallel Figure 4 Cable schematic for series Pos of first panel co...

Page 8: ...irst panel connects to Neg of next panel using branch connectors and so on and terminating with the Neg of the solar charge controller Optimized for MPPT or PWM solar charger Figure 6 Cable schematic...

Page 9: ...tput of a solar panel is proportional to the amount of sunlight that reaches the solar cells Therefore any build up of dust or dirt on the surface of the solar panel will result in a loss of power Thi...

Page 10: ...ight Loose or no DC cable connections Connect DC cables to the battery and solar panel and tighten terminal connections Fuse is blown Replace the blown fuse with a 30A 32V green ATC blade fuse Specifi...

Page 11: ...50 PV Connector Assembly Tool PN 708 0060 Mounting Hardware PN 708 0070 Remote Battery Temperature Sensor PN 708 0080 Roof Entry Cable Plate PN 708 0090 Solar and Battery Cables Starter Kit 10 AWG 20...

Page 12: ...1 800 670 0707 1 408 987 6030 customerservice xantrex com http www xantrex com power products support http www xantrex com 975 1028 01 01 Rev A January 2021 Printed in USA...

Reviews: