background image

XT-DL-IRK

DinkyLink

 IR Receiver Kit

Plasma / LCD / LED / CFL Friendly IR Receiver

INSTALLATION INSTRUCTIONS

Summary of Contents for XT-DL-IRK

Page 1: ...XT DL IRK DinkyLink IR Receiver Kit Plasma LCD LED CFL Friendly IR Receiver INSTALLATION INSTRUCTIONS...

Page 2: ...Terminator SPECIFICATIONS Infrared carrier frequency bandwidth 25 60 kHz Reception range Up to 80 feet Reception angle 60 degrees Cable requirements See INSTALLATION below Max Transmission length 1 m...

Page 3: ...s additional 3 conductor may be required and can be connected to the terminals on the connecting block 2 Connect the Emitters to the connecting block The yellow connector is installed to the yellow pl...

Page 4: ...44 Connecting Block REMOTE ROOM MAIN ROOM Hand Hel d Remote 3 Terminal Block not included 3 Conductor Inter room Cable unshielded OK 7 Ribbon Cable A V Receiver DVD IR Photodiode Red Talkback LED Sate...

Page 5: ...e plug and strip and tin the leads for certain applications REMOTE ROOM MAIN ROOM Block not included 3 Conductor Inter room Cable unshielded OK e IR IN S IR RCVR LOCK 12V GND 12VDC 12 VDC GND STATUS I...

Page 6: ...is within reach of the 7 foot cable The 3 5mm stereo type mini plug is connected to the IR RCVR jack on the Xantech Connecting Block PLACEMENT The IR receiver should be located so that it is not dire...

Page 7: ...can now be concealed for clean room design In addition a centralized IR receiver means there is only one IR target resulting in improved remote control interaction Featuring color coded connectors a...

Page 8: ...on the 789 44 Connecting Block ITEM B Plug the AC end of the PS12 0 5 Power Supply ITEM E into a un switched 120V AC Line outlet STEP 2 Connect the 3 5mm stereo mini plug from the DL IR Receiver ITEM...

Page 9: ...ded The YELLOW connector connects to the YELLOW receptacle PS12 0 5 Remote 12VDC 12 VDC CONNE 12VDC 12 VDC GND STATUS IR IN EMITTERS 789 44 CONNECTING BLOCK IR RCVR Satellite Receiver 283D Emitter 283...

Page 10: ...oper voltage Verify supply is a 12VDC regu lated supply reading between 11 5 to 13VDC under load Should be using Power Supply Model PS12 0 5 12VDC Regulated 200mA or PS12 1 25 12VDC Regulated 1 2A 5 O...

Page 11: ...cent lighting 4 EMI induced noise This can be due to light dimmer controls or other radiating electronic devices PC s or any poorly shielded electronic device Reposition IR Receiver and or cabling awa...

Page 12: ...any of the following Sunlight florescent Lighting or Plasma Displays In this case use either a SUN filter SUNKIT or any of our Plasma CFL Friendly IR Receivers DL85 95 HL85 95 ML85 95 WL85 95 These c...

Page 13: ...dly IR Receivers DL85 95 HL85 95 ML85 95 WL85 95 These can also be used in direct sunlight and in the presence of tube style fluorescent lighting 3 Long Wire Runs shielded wire typi cally of 100 feet...

Page 14: ...n the Emitter to a position that is suitable for the unit Use a 283 or 286D Blink style emitter they have a lower output than non blink emitters 282 and 284M If the com ponents do not need to be contr...

Page 15: ...tem 2 Verify Emitter 283D or 286D Blink Style ONLY Remove the power supply from the connecting block and all Emitters from the output Place a jumper wire on the connecting block between IR and 12v Rec...

Page 16: ...dental or consequential damages Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specifi...

Reviews: