Page 2
Model SPLCDCB100
SPECIFICATIONS:
•
Power Input: 16VDC (2.1mm Coaxial Jack)
•
Power Output: 12VDC (100mA Max)
•
SmartPad LCD™ Connection: 4-Screw Terminal (16VDC Pass thru, GND, Status, IR Input)
•
IR Receiver Connection: 3.5mm Quick Connect Stereo Mini Jack & 4-Screw Terminal (12VDC output, GND,
STATUS, IR Input)
•
Ten IR Emitter Ports (3.5mm Mono Mini Jack)
•
High IR Output: 1Amp Current Output for expansion to 790-00 Connecting Block (3.5mm Mono Mini Jack)
•
Dimensions: 6-7/8” L x 2-3/4” W x 15/16” H (175mm L x 70mm W x 24mm H)
•
SPLCDPS1 16VDC Power Supply (not included) powers one SPLCD and up to four IR Receivers.
•
SPLCDPS4 16VDC Power Supply (not included) powers up to four SPLCD’s and up to four IR Receivers.
•
Maximum Emitter Output Current: 12mA
INSTALLATION
POWER WIRING:
1. Connect the 16VDC SPLCDPS1 or SPLCDPS4 power supply to the 2.1mm coaxial power input jack (labeled
16VDC).
2. Plug the AC Adaptor into an un-switched AC Outlet.
SPLCD IR WIRING:
1. Wire 4-Conductor 18AWG from the SPLCD’s IR OUT, GND, STATUS (optional) and +16VDC terminals back to
the appropriate terminals of the SPLCDCB100 Connecting Block. 18AWG can be run in excess of 1000ft. See
Figure 1
for wiring examples.
2. For more than one SPLCD Controller, connect in parallel directly on the 4-screw WECO terminal or use a CB-18
parallel connecting block to neatly combine up to 4-SPLCD controllers (Requires SPLCDPS4 Power Supply).
283M
Blink-IR
Mouse Emitter
283M
Emitter
283M
Emitter
DVD
Satellite Receiver
AV
Receiver
SPLCD-CB
Amplified Connecting Block
EMITTERS
16 VDC
IR
RCVR
SPLCD-CB
AMPLIFIED
CONNECTING BLOCK
®
+12 VDC OUT
GND
STATUS
IR IN
HIGH
IR
OUT
SPLCD
ONL
Y
+16 VDC
GND
STATUS
IR IN
IR
TB
SPLCDPS1
16VDC Power Supply
(To Un-Switched AC Outlet)
SPLCD57G
IR BUS
IR IN
ZONE
CONTROLLER
EXPANSION
SERIAL
GND
IR OUT
+16V IN ONL
Y
GND
ST
ATUS
IR BUS
+12V OUT
GND
GND
IR IN
+12V IN TO EXPANSION
IR RECEIVER ENABLE
TERMINATION
SMARTPAD LCD 5.7
GRAPHIC TOUCHPANEL
IR RECIEVER
CAUTION:
SPLCD ONLY!
DO NOT CONNECT
12V DEVICE
Figure 1 – Basic Connection: Connecting the SmartPad LCD™ Controller to the SPLCDCB100
Caution:
Remember, the STATUS output can be either an Input (5-30VDC from remote device) to trigger a
Macro within the SPLCD, give LED indication of a Zones power status, or it can be an OUTPUT (+12VDC from
the SPLCD) to trigger some other external device. This is important to note before STATUS wiring is made
between the SPLCD and the other device.
© 2004 Xantech Corporation