Individual ON/OFF of Amp Pairs

.   Permits Standby ON/OFF control of individual channel pairs.  Specifically, it 

permits the STATUS outputs (12 Volts On/Off) of Xantech ZPR68 zones to switch the Standby of the PA635 
channel pairs (

CI

) On and OFF with zone ON and OFF commands.  

 

Remote Master ON/OFF

.   Allows the entire PA635 to be powered ON and OFF by a positive DC voltage ranging 

between 5 and 30 volts (16mA @ 12V).  Specifically, it permits the 12 Volt common CO (Control Output) on the 
Xantech ZPR68 to power one or more PA635's ON and OFF automatically with first zone ON and last zone OFF 
commands. 
 

CAUTION

:  When powering up multiple PA635’s, a delay of 2 or more seconds should be incorporated between 

“power on” using multiple Xantech AC2’s. 
 

Default settings

.  As received from the factory, Volume level is set to 1 Volt for 3 Watts output, Balance is 

centered and Mute is OFF, for all channels.  Also, pressing the LEVEL (System) RESET switch 2 times within 1 
second restores all factory defaults.  The PA635 will always return to last set values (volume, etc.) after main 
power shut down or after any power interruptions.   
 

Low Impedance Capability

.  Each amplifier is 4-Ohm safe under music conditions in stereo mode and 8-Ohm 

safe when bridged.  This means, for instance, that you can drive two pairs of 8-Ohm speakers in stereo mode in 
each zone with ease and safety. 
 

Auto Protection Circuit

.  Protects the PA635 if a short or very low impedance is detected at the speaker 

terminals or excessive temperatures are reached.  Each amplifier pair is protected separately.  Normal operation 
is restored automatically when the short is removed or when temperatures drop sufficiently. 
 

PA635 PANEL AND FEATURE DESCRIPTIONS

 (refer to Figure 2)

 

 

1

2

3

POWER

PA635 

SIX CHANNEL AMPLIFIER

1

2

3

2

3

1

2

4

 

 

Figure 2

 – PA635 Front Panel – Features and Functions 

 
1. 

Front Panel

. 19" x 3 ½" panel designed for mounting into a standard 19" Rack Panel. 

 
2. 

Rack Panel Handles

 
3. 

POWER Switch

. When pressed to the IN position, power is applied to the PA635 [provided the rear panel 

master AC LINE ON/OFF Switch, item 17, is placed in the ON (I) position].  This is the MANUAL ON position.  
When pressed again, it releases to the OUT position (MANUAL OFF), turning the unit OFF. 

 

 
In addition, this switch must be left in the MANUAL OFF (OUT) position to permit an external DC Control 
Voltage to power the PA635 ON and OFF.  Refer to "

REMOTE MASTER ON/OFF CONTROL

" terminals, 

item #13. 

Summary of Contents for PA635

Page 1: ...ROL 6 PHYSICAL LOCATION AND MOUNTING 9 CONNECTING THE PA635 10 Stereo Mode Connections 10 Speaker Phasing 11 Bridged Mode Connections 11 Typical Applications 12 A Basic Common IR Bus System Dedicated...

Page 2: ...rom an RC68 or RC68 The maximum input sensitivity at full volume is 0 5 volts for rated output 35 Watts channel Local or Common Bus Each stereo pair can be fed audio individually via their LOCAL input...

Page 3: ...any power interruptions Low Impedance Capability Each amplifier is 4 Ohm safe under music conditions in stereo mode and 8 Ohm safe when bridged This means for instance that you can drive two pairs of...

Page 4: ...to Red NOTE Red indicates that volume gain setting is approaching maximum not an indication of power output level WARNING TURN POWER OFF BEFORE CHANGING MODES CAUTION RISK OF ELECTRIC SHOCK DO NOT OP...

Page 5: ...rol in disabled Changes CI control to IR control of Standby ON OFF CI enables when 5 to 30 VDC is applied to CI for 2 or more seconds See also item 11 NOTE The PA635 will always return to last set val...

Page 6: ...with the AC Power ON OFF state of the entire PA635 It does not respond to a Common IR OFF ON Standby condition 16 Grounding Screw Provides a means for chassis connection to earth ground or to other A...

Page 7: ...fixed preset levels on the PA635 This is useful when setting up audio scene ambiance levels for rooms or partial mute actions The RC68 buttons that select a fixed level attenuation below Max Volume i...

Page 8: ...In addition to MUTE OFF the muted condition can be released with VOLume item 8 Preset Level item 2 and Balance items 4 5 commands 8 Volume Up Down Commands When pressed in individual steps volume inc...

Page 9: ...nd the escape of warm air NOTE Do not remove feet in shelf top installations 3 If the cabinet contains other heat generating components or you are using several PA635 s in a large multi zone system yo...

Page 10: ...2 Slide the MODE switch to the STEREO position 3 Using good quality speaker wire connect the individual speaker leads to the 4 terminal SPEAKER connectors on the PA635 as shown 4 The PA635 is 4 Ohm sa...

Page 11: ...ds to one of the speakers Pick the connection that delivers a solid center image between the speakers as well as best bass response Bridged Mode Connections In general it is recommended that the BRIDG...

Page 12: ...evel volume controls and their attendant power losses and reduced sound quality A Basic Common IR Bus System Dedicated Keypads and Remotes A typical system using a low cost approach is shown in Fig 8...

Page 13: ...ng Block 780 80 J Box IR Receiver ROOM 2 R L ST G V IR ROOM 1 R L Smart Pad 3 ST G V IR IR CONFIRM V V POWER 15VAC VIDEO AUDIO LEFT INPUT OUTPUT AUDIO RIGHT 1 2 3 4 G IR IN SYLMAR CA MADE IN U S A RS4...

Page 14: ...ayers of complexity and cost that would best be handled by a ZPR68 10 10 When connecting speakers for each room be sure to observe correct polarities as shown in Fig 6 A Basic Dedicated IR System Non...

Page 15: ...G A B A B A B ZONE 4 ZONE 5 ZONE 6 12 OUT G SYLMAR CA MADE IN U S A ZONE EMITTERS ZONE EMITTERS 796 20 SIX ZONE CONNECTING BLOCK EXPANDER 780 80 J Box IR Receiver ROOM 2 R L ST G V IR ROOM 1 R L Smart...

Page 16: ...item 10 Fig 3 NOTE Do not use the 220 Ohm resistor when connecting to the CO terminals of a ZPR68 REMOTE MASTER ON OFF CONTROL 5 30 VOLTS DC LEFT RIGHT COMMON AUDIO BUS CI GROUND STATUS IR IN WARNING...

Page 17: ...ed by IR control of the ZPR68 10 The PA635 amplifier pairs are all set to the default volume level setting by pressing the LEVEL System RESET button refer to item 9 Fig 3 AC Power Management of the en...

Page 18: ...peakers as necessary to obtain higher impedance PA635 does not turn OFF when REMOTE input voltage goes to 0 Volts Be sure that the POWER switch item 3 Fig 2 is set to the MANUAL OFF Out position PA635...

Page 19: ...t 1 Watt 3dB 12 Hz to 55 kHz Input Sensitivity at rated power stereo mode input gain IR controlled setting Max 0 5 V Default 1 0 V Minimum Off Input Impedance Local Inputs 22 kOhms Common Audio Bus In...

Page 20: ...Page 20 Model PA635 2001 Xantech Corporation Part No 08901150 Rev A 01 02 2002...