background image

Page 2 

 

Model PA635 

 

© 2001 Xantech Corporation. 

GENERAL INFORMATION 

 
To enhance the ease of installation and obtain optimum performance from the PA635, we recommend that you 
first become familiar with all its features and special capabilities by studying the descriptions and instructions in 
this manual.  
 
The PA635 was designed to meet the audio power amplifier needs of custom installed multi-room, multi-zoned 
systems with high sonic quality.  Common and Local IR control of Volume, Mute, Balance and OFF, for each 
channel pair, is provided.  Its bridgeable 6-5-4-3 multi-channel capability permits a wide variety of uses, such as 
enough channels to run surround sound home theater or multi-room applications.  Specific features and 
technology are as follows: 
 

1

2

3

POWER

PA635 

SIX CHANNEL AMPLIFIER

 

 

Figure 1

 – The Model PA635 

 
Cost/Size Efficiency

.  The PA635 features 6 conservatively rated 35-watt power amplifiers. This permits each 

PA635 to drive 3-zones in a multi-zone system, each with a 35 watts/channel stereo amplifier per zone.  The rack 
mountable low profile design, using a large single multiple filtered power supply, delivers high quality at a 
reasonable price. 
 

IR Controlled Volume Level

.  Volume can be ramped from zero output to maximum for individual channel pairs, 

or, as group through the Common Bus inputs, using IR volume control commands from an RC68+ (or RC68).  
The maximum input sensitivity at full volume is 0. 5 volts for rated output (35 Watts/channel).  
 

Local or Common Bus

.  Each stereo pair can be fed audio individually via their LOCAL inputs from differing 

zones or sources.  In addition, a single source can be fed, via the COMMON Bus, to some or all stereo pairs as 
desired. This flexibility permits the installer to drive as many as three rooms in stereo as a single zone system, or 
three rooms in stereo as a three-zone system --- or divide them up for a combination of both.  
 

Volume Setting Capabilities

. The installer has the option of using the volume control of the PA635 as the sole 

volume control for a zone or the system, or to adjust the PA635 volume to a desired fixed level and use the 
volume action of a connected preamp instead.   
 

Max-V Setting

. This allows the amplifier to be set to deliver a controlled maximum sound level into a zone when 

the volume is ramped to maximum.  This acts as a volume limiter for the system (e.g. to prevent the kids from 
over-driving wall speakers, etc.). 
 

Output Flexibility (6-5-4-3).

  Each of the six amplifiers can be driven singly or bridged to allow several channel 

and power output capabilities.  It can be configured into seven power packages as follows: 
Six 35-watt amplifiers - 6 total. 
One 150 and four 35-watt amplifiers - 5 total. 
Two 150 and two 35-watt amplifiers - 4 total. 
Three 150-watt amplifiers - 3 total. 
This gives the PA635 great flexibility for use in many applications, such as driving surround sound speaker 
systems, in addition to multi-room.

 

 

Summary of Contents for PA635

Page 1: ...ROL 6 PHYSICAL LOCATION AND MOUNTING 9 CONNECTING THE PA635 10 Stereo Mode Connections 10 Speaker Phasing 11 Bridged Mode Connections 11 Typical Applications 12 A Basic Common IR Bus System Dedicated...

Page 2: ...rom an RC68 or RC68 The maximum input sensitivity at full volume is 0 5 volts for rated output 35 Watts channel Local or Common Bus Each stereo pair can be fed audio individually via their LOCAL input...

Page 3: ...any power interruptions Low Impedance Capability Each amplifier is 4 Ohm safe under music conditions in stereo mode and 8 Ohm safe when bridged This means for instance that you can drive two pairs of...

Page 4: ...to Red NOTE Red indicates that volume gain setting is approaching maximum not an indication of power output level WARNING TURN POWER OFF BEFORE CHANGING MODES CAUTION RISK OF ELECTRIC SHOCK DO NOT OP...

Page 5: ...rol in disabled Changes CI control to IR control of Standby ON OFF CI enables when 5 to 30 VDC is applied to CI for 2 or more seconds See also item 11 NOTE The PA635 will always return to last set val...

Page 6: ...with the AC Power ON OFF state of the entire PA635 It does not respond to a Common IR OFF ON Standby condition 16 Grounding Screw Provides a means for chassis connection to earth ground or to other A...

Page 7: ...fixed preset levels on the PA635 This is useful when setting up audio scene ambiance levels for rooms or partial mute actions The RC68 buttons that select a fixed level attenuation below Max Volume i...

Page 8: ...In addition to MUTE OFF the muted condition can be released with VOLume item 8 Preset Level item 2 and Balance items 4 5 commands 8 Volume Up Down Commands When pressed in individual steps volume inc...

Page 9: ...nd the escape of warm air NOTE Do not remove feet in shelf top installations 3 If the cabinet contains other heat generating components or you are using several PA635 s in a large multi zone system yo...

Page 10: ...2 Slide the MODE switch to the STEREO position 3 Using good quality speaker wire connect the individual speaker leads to the 4 terminal SPEAKER connectors on the PA635 as shown 4 The PA635 is 4 Ohm sa...

Page 11: ...ds to one of the speakers Pick the connection that delivers a solid center image between the speakers as well as best bass response Bridged Mode Connections In general it is recommended that the BRIDG...

Page 12: ...evel volume controls and their attendant power losses and reduced sound quality A Basic Common IR Bus System Dedicated Keypads and Remotes A typical system using a low cost approach is shown in Fig 8...

Page 13: ...ng Block 780 80 J Box IR Receiver ROOM 2 R L ST G V IR ROOM 1 R L Smart Pad 3 ST G V IR IR CONFIRM V V POWER 15VAC VIDEO AUDIO LEFT INPUT OUTPUT AUDIO RIGHT 1 2 3 4 G IR IN SYLMAR CA MADE IN U S A RS4...

Page 14: ...ayers of complexity and cost that would best be handled by a ZPR68 10 10 When connecting speakers for each room be sure to observe correct polarities as shown in Fig 6 A Basic Dedicated IR System Non...

Page 15: ...G A B A B A B ZONE 4 ZONE 5 ZONE 6 12 OUT G SYLMAR CA MADE IN U S A ZONE EMITTERS ZONE EMITTERS 796 20 SIX ZONE CONNECTING BLOCK EXPANDER 780 80 J Box IR Receiver ROOM 2 R L ST G V IR ROOM 1 R L Smart...

Page 16: ...item 10 Fig 3 NOTE Do not use the 220 Ohm resistor when connecting to the CO terminals of a ZPR68 REMOTE MASTER ON OFF CONTROL 5 30 VOLTS DC LEFT RIGHT COMMON AUDIO BUS CI GROUND STATUS IR IN WARNING...

Page 17: ...ed by IR control of the ZPR68 10 The PA635 amplifier pairs are all set to the default volume level setting by pressing the LEVEL System RESET button refer to item 9 Fig 3 AC Power Management of the en...

Page 18: ...peakers as necessary to obtain higher impedance PA635 does not turn OFF when REMOTE input voltage goes to 0 Volts Be sure that the POWER switch item 3 Fig 2 is set to the MANUAL OFF Out position PA635...

Page 19: ...t 1 Watt 3dB 12 Hz to 55 kHz Input Sensitivity at rated power stereo mode input gain IR controlled setting Max 0 5 V Default 1 0 V Minimum Off Input Impedance Local Inputs 22 kOhms Common Audio Bus In...

Page 20: ...Page 20 Model PA635 2001 Xantech Corporation Part No 08901150 Rev A 01 02 2002...

Reviews: