![background image](http://html1.mh-extra.com/html/xantech/hd44c/hd44c_installation-instructions-manual_3161741004.webp)
08905071B
-
4
-
RS232 COMMAND STRUCTURE
Where:
{CR
#
} – Carriage Return (0x0D)
{
z#
} - Zone Number. Range is 1..4 (1..16 if expanded)
{
s#
} - Source Input Number. Range is 1..4
{
0/1
} – Either 0 (zero) or 1 (one). 0 – Off, 1 – On.
NAME
COMMAND
RETURN
REMARKS
!{
z#
}
PR
01+
To turn on Zone 2: !2PR1+ or !02PR1+ or
!2PR01+ or !
Zone Power
!{
z#
}
PR
00+
OK{CR}
ERROR{CR}
To turn off Zone1: !1PR0+ or !01PR0+ or
!1PR00+ or !
Zone Power
Toggle
!{
z#
}
PT
+
OK{CR}
ERROR{CR}
All Zones Off
!EO+
OK{CR}
ERROR{CR}
Turns all the zones off.
All Zones On
!EA+
OK{CR}
ERROR{CR}
Turns all the zones on.
Zone Restore All
!RF+
OK{CR}
ERROR{CR}
Restore all the Zone-to-Source routing to the
current selection: !RF+
Input (Source)
Select
!{
z#
}
SS
{
s#
}+
OK{CR}
ERROR{CR}
To set Zone 1 to Source Input 4: !1SS4+
Ping Expansion
Port
!
RP
+
OK{CR}
ERROR{CR}
Request that any unit connected to the expansion
port respond with a ping.
Return Ping to
Xantech port
!
SP
+ +
Returns a +. Meant for inter-expansion box
communications.