08905071B
-
5
-
RS232 QUERIES
Where:
{CR
#
} – Carriage Return (0x0D)
{
z#
} - Zone Number. Range is 1..4 (1..16 if expanded)
{
s#
} - Source Input Number. Range is 1..4
{
0/1
} – Either 0 (zero) or 1 (one). 0 – Off, 1 – On.
NAME
QUERY
RETURN
EXAMPLE
RETURN
EXPLANATION
Zone Power
?{
z#
}
PR
+
?{
z#
}
PR
{
0/1
}+ ?4
PR
0+{CR}
Power in zone 4 is OFF.
Input Select
?{
z#
}
SS
+ ?{
z#
}
SS
{
s#
}+
?4SS3+{CR}
Zone 4 currently has source 3 selected.
System Info
?
SI
+
?SI
{Device:
HD44,
Device Cde:
000C,
Hardware Cde:
0000,
Reserved Cde:
0000,
Firmware Ver:
X.Y.Z}+
?SI
Device:
HD44, Device
Cde:
000C,
Hardware Cde:
0000,
Reserved Cde:
0000,
Firmware Ver:
1.1.0
This command is used only with single unit
systems. Note this is command does not
trickle down to the expansion port.
X = Major
Y = Minor
Z = Release