08905107C
-
5
-
C. Security Code
This six digit number can be used to access the programming mode. The security code has been
factory set to
845464
. It is recommended that you change the security code to a personal 6 digit
number. To change the security code, access programming (see
Programming
section
A
). Enter six
digits 0-9 followed by
#47
. If you have forgotten your security code, follow the steps in
Programming
section
A, 2. Accessing the Programming Mode Locally (Security Code Bypass Mode)
.
Note:
The security code must be six digits in length and can NOT contain a *
or #.
D. DIP Switch Programming
SWITCH
POSITION
DESCRIPTION
1
OFF
Auxiliary Contact Mode.
1
ON
Doorbell Mode (Factory setting).
2
OFF
Normal Operation Mode (Factory setting).
2
ON
Security Code Bypass Mode.
3
OFF
Entry Phone automatic disconnect (CPC) disabled.
3 ON
Entry Phone automatic disconnect (CPC) enabled
(Factory setting).
4
OFF
Entry Phone busy signal disabled.
4
ON
Entry Phone busy signal enabled (Factory setting).
E. Privacy Number
The “Privacy Number” is factory disabled so an entry phone off-hook will automatically ring the house
phones. If a “Privacy Number” is programmed, the visitor must Touch Tone dial the number to be able
to call into the house. The “Privacy Number” may be from 1 to 6 digits and is stored in location “
#00
”.
To disable the “Privacy Number,” clear the number’s memory location by entering “
#00
” without any
previous digits.
F. Keyless Entry Codes and One Time Use Keyless Entry Codes
Each entry phone may have a combination of up to 6 keyless entry codes or one time use keyless
entry codes for Touch Tone keyless entry. The keyless entry codes may be from 4 to 6 digits in length
and are stored in locations
#11
-
#16
for entry phone 1,
#21 - #26
for entry phone 2,
#31 - #36
for
entry phone 3, and
#41 - #46
for entry phone 4. Up to 6 master keyless entry codes may be from 4 to
6 digits in length and are stored in locations
#51 - #56
. The master keyless entry codes can be used
at any entry phone. To change any of the keyless entry codes to one time use, insert a * in front of
the specific memory location during programming (ie: “*
#11
”). To clear any keyless entry codes,
simply enter the location number (ie: “
#11
” or “*
#11
”) without any previous digits.