![background image](http://html1.mh-extra.com/html/xantech/crm-wic/crm-wic_reference-manual_3156372048.webp)
48
Fault Codes
Fault Code Fault Description
1
Function parameter out of range / item specified does not
exist
2
Timed out waiting for a mutex or shared resource
3 Memory
allocation
failure
4
Configuration does not support action (ie. setting a Digital
I/O output when it is configured as an input)
5
Failed to find entry in database (registry or FRAM)
6
Failed to store persistent database (registry or FRAM),
settings might not be saved
7
Some internal error occurred that does not fit another
category. Must use extended error information to
diagnose.
8
An expected file format was invalid
9
IR signal too strong, receiver is overloaded
10
IR signal too weak
11
Other IR capture error
Using Macromedia Flash
You may access all WACP RPCs using HTTP post. In Flash, you may accomplish this using LoadVars{}
and sendAndLoad(). An example for making these calls follows.
STEP 1: Pass CRM-WIC IP Address to Flash
To begin, you must pass the IP address of CRM-WIC to your Flash file. There is more than one way to
do this, but below, we describe one sample method using JavaScript. NOTE: In this script, the .html
and.swf files must reside on the CRM-WIC to determine the IP address.
First, at the top of the .html file in which you are embedding your flash file (here, the name of the file is
"MyCRM-WICShockWaveFlashFile.swf"), insert this bit of script:
<script type="text/javascript" language="JavaScript">
thispage = location.href;
URLarr = thispage.split("/");
theIP = URLarr[2];
theFILE = "MyCRM-WICShockWaveFlashFile.swf";
</script>
Summary of Contents for CRM-WIC
Page 1: ...Reference Manual Programming Guide Room Monitor Web Intelligent Controller Model CRM WIC...
Page 8: ...8 Hardware User Interface Hardware User Interface for the CRM WIC...
Page 16: ...16 For full details see the RPC section at the end of this manual...
Page 43: ...43 This expression resolves to this value 0 1 4 3 1 Hello Hello 0...
Page 98: ...98 Index...