Controllers

599-00

• When the chair is no longer occupied, the SPST switch opens, triggering another set of sequenced

commands.  These, in turn, could cause the lights to brighten, the drapes to open and the music to turn
off.

• Many other scenarios are possible, limited only by the imagination and needs of the installer and user.

Driving a Relay

There are times when you may want to drive a relay directly from the ON/OFF outputs of the 599-00 to trigger
a device, such as a power amplifier, drape pulls, screen drops, etc. -- devices that require a momentary dry
switch closure.  

Fig. 4

 illustrates how this can be done.

OFF

ON

GND

+12V

IN +

IN –

GND

+12V

599-00

PULSED SWITCHING

MODULE

SYLMAR, CA • MADE IN U.S.A.

®

786-00 

Power Supply

(Most 5 to 12 VDC unregulated
power supplies will work)

+

Plug into the
AV System's
Switched AC
Outlet

1N4001

Back EMF Diode
(see 

CAUTION

 above)

+

1N4148

Isolation Diodes

(see text)

781RG

Power Supply

To 120 VAC
(unswitched)

Relay

(Coil: 6 VDC

@ 20 mA)

N/O

To device requiring a

momentary dry switch

closure for activation

Fig. 4

 Driving a Relay For a Momentary Dry Closure

OFF

ON

GND

+12V

IN +

IN –

GND

+12V

599-00

PULSED SWITCHING

MODULE

SYLMAR, CA • MADE IN U.S.A.

®

From a System's 4 to
12 VDC non-momentary
control voltage output

+

1N4148

Isolation Diodes

(see text)

781RG

Power Supply

To 120 VAC
(unswitched)

To an amplifier or other

device requiring a

momentary trigger

pulse for power On/Off or

other type of activation

+

+

• The DC control voltage may be a power supply adapter connected to the switched outlet of an AV receiver,

as illustrated, or any other 4 to 12 VDC controlling source.

• The two 1N4148 signal type diodes provide isolation between the ON & OFF outputs, yet combine them

so that a momentary pulse drives the relay for both the On and Off transitions.

CAUTION:

  A 1N4001 diode (or equivelant) 

must

 be connected in parallel with the relay coil as shown.

This prevents high relay coil back EMF from damaging the 599-00 during switching transients.

DC On/Off to Momentary On/Off

Some preamps, or A/V control centers, have a 0 to 12 VDC output control port for the express purpose of
turning a companion amplifier, with a non-momentary DC control voltage port, On and Off.

However, some amplifiers (or other devices), have a control port that requires a momentary pulse to trigger
the On/Off condition.  The 599-00 is an ideal module for making this conversion.

Fig. 5

 illustrates how this is done.

• The non-momentary DC control voltage from the preamp or other controller, is connected to the 

IN+

 and

IN–

 terminals as shown.

Fig. 5

 DC On/Off to a Momentary

Pulsed On/Off Trigger