background image

2

599-00

• When the AM/FM receiver is turned OFF manually, an IR command can also STOP the DVD player and

turn it OFF.

• To do this, the presence or absence of a constant ON and OFF DC voltage must be converted to

momentary pulses to properly operate the Model 590.

• This can be done by using the Model 599-00 connected as shown in 

Fig. 2

.

• By plugging the Model 786-00 power supply into the switched AC outlet on the back of an A/V Receiver,

a constant 12 VDC is applied to the 599-00 when the Receiver is powered ON. The 599-00 generates a
short pulse (+12V, 100 mSec) at its 

ON

 terminal when it first sees +4 to +12V DC at its IN+ and IN–

terminals.

• Similarly, it will generate a short pulse at its 

OFF

 terminal (+12V, 100 mSec) when the +4 to +12 volts drops

to 0 volts (the A/V Receiver is turned off). Refer to 

Fig. 6

.

• This short pulse operation, therefore, permits momentary switches connected to other inputs on the 590

(such as inputs 1 and 2, as in 

Fig. 2

) to execute other system commands uninhibited.

Using a Sensing Switch

Fig. 3

  shows another example of

how a DC control voltage is con-
verted to momentary ON and OFF
pulses.

• For instance, a special SPST

sensing switch, as shown, could
be mounted in the springs of an
over-stuffed chair.

• When someone sits down in the chair, the SPST switch closes, causing the 599-00 to trigger a sequence

of IR commands stored in the 590.  The IR commands, for instance, could cause the room lights to dim,
the drapes to close, and music to emanate from the speakers.

Fig. 2

  Using a 599-00 to Trigger the

Inputs on a 590 Programmable
Controller

OFF

ON

GND

+12V

IN +

IN –

GND

+12V

599-00

PULSED SWITCHING

MODULE

SYLMAR, CA • MADE IN U.S.A.

®

1

12VDC

12VDC

1 2 3 4

BANK

+

2

3

4

5

6

7

8

9 10 11

14 15 16 O G

+

12 13

To 120 V AC
(unswitched)

Momentary
Switches for
other system devices

Plug into the
Switched AC
Outlet

+

+12V DC

ON

786-00 

Power

Supply

Ground or "

"

return wires.

590-00 

Programmable Controller  (rear panel)

RES DEL SEQ PGM

786-00

Power Supply

(Most 5 to 12 V DC

unregulated power

supplies will work)

GND (–)

12VDC

+12 VDC

GND

STA

TUS

IR IN

EMITTERS

IR

RCVR

789-44

CONNECTING BLOCK

®

DVD Player

A/V Receiver

To Emitters

on other

system

devices

283M

Blink IR Emitter

789-44

Connecting

Block

IR from other sources, such
as IR Rec'rs, Keypads, etc.

OFF

ON

GND

+12V

IN +

IN –

GND

+12V

599-00

PULSED SWITCHING

MODULE

SYLMAR, CA • MADE IN U.S.A.

®

Connect to the

590-00 in the same

manner as in 

Fig. 2

.

SPST Sensing

Switch

OFF

ON

Fig. 3

 SPST Sensing Switch Application

Reviews: