background image

 

 

 

08905099B 

 

  - 

ADVANCED WIRING CONFIGURATION 

480-95 may also be used in conjunction with other Xantech IR Receivers by simply wiring in parallel 
on a Connecting Block such as the 791-44 Amplified Block as shown in the figure below. 
 

1.  Connect all IR Receivers in parallel at the terminals of the connecting block as shown in the 

figure below.  

2.  Plug in the 2.1mm Coaxial power plug of the 781RG (or 782) Power supply (not included) into 

the jack labeled PWR on the 789-44CB. 
Note: Up to 7 IR Receivers may be connected in parallel with a single 781RG power supply. If 
more IR Receivers or any Keypads are required, check total current requirements and 
increase power supply current rating accordingly; i.e. 782-00 – 1.2A Power Supply) 

3.  Plug in the Emitters 3.5mm mono mini plug (282, 284, 283 or 286 series) into the Emitter 

Outputs on the 791-44. 

 

120 V AC

(Unswitched)

782-00

Power Supply

490-00 

Series

Micro Link™

IR Receivers

3-Wire

Cable

IR OUT

GND

+12V

Red

Stripe

3-Wire

Cable

IR OUT

GND

+12V

480-85

Dinky Link™

IR Receiver

Red

(or white)

Stripe

REMOTE ROOM 1

780-80

J-Box IR Receiver

7 Foot 3-Conductor

Cable with Quick

Connect Stereo

Mini Plug

490-30

 

Series

Micro Link™

IR Receivers

REMOTE ROOM 2

REMOTE ROOM 3

REMOTE ROOM 4

GND

IR

OUT

+12V

3-Conductor

Room-to-

Room Cables

(Home Runs)

+12VDC
STATUS
GND
IR OUT

780-80

IR RECEIVER

®

Satellite 

Receiver

VCR

AV 

Receiver

CD

 Changer

Tape

 DecK

791-44

Amplified

Connecting Block

283M

 Blink-IR™

283M

 Blink-IR™

283M

 Blink-IR™

283M

 Blink-IR™

480-95

283M

Blink-IR™

Mouse Emitter

+12 VDC
GND

EMITTERS

12 
VDC

HIGH

IR

OUT

STATUS
IR IN

IR

RCVR

791-

44

AMPLIFIED

CONNECTING BLOCK

®

3-Wire

Cable

IR OUT

GND

+12V

Red

(or white)

Stripe

 

 

Summary of Contents for 480-95

Page 1: ...calls These small IR receivers have been designed for mounting in very small spaces They may be mounted under shelf edges cabinet ledges in wall speakers etc anywhere an inconspicuous appearance is d...

Page 2: ...ally it should be placed somewhere around the Display with the front of the receiver flush with the front of the Display If the 480 95 needs to be placed in front of the display such as on an adjacent...

Page 3: ...ault is 12 o clock position Clock wise CW Increase sensitivity Counter Clock wise CCW Decrease sensitivity APPLICATION WIRING A typical system with a 480 95 781RG Power Supply and 283M Emitter plugged...

Page 4: ...3 Plug in the Emitters 3 5mm mono mini plug 282 284 283 or 286 series into the Emitter Outputs on the 791 44 120 V AC Unswitched 782 00 Power Supply 490 00 Series Micro Link IR Receivers 3 Wire Cable...

Page 5: ...en IR Receiver and the Connecting Block is open Recheck wiring 4 Power Supply not putting out proper voltage Verify supply is a 12VDC regulated supply reading between 11 5 to 13VDC under load Should b...

Page 6: ...sunlight and in the presence of tube style florescent lighting 4 EMI induced noise This can be due to light dimmer controls or other radiating electronic devices PC s or any poorly shielded electroni...

Page 7: ...ent Lighting or Plasma Displays In this case use either a SUN filter SUN480 SUN490 SUN780 or any of our CFL Friendly IR Receivers 291 80 480 80 780 80 For Plasma Interference use the 490 90 or 780 90...

Page 8: ...80 780 80 For Plasma Interference use the 490 90 or 780 90 Plasma Friendly IR Receivers These can also be used in direct sunlight and in the presence of tube style florescent lighting 3 Long Wire Runs...

Page 9: ...er the Emitter PN MS1 The rounded non stick side of the emitter is a hi output side and can reflect off other devices and overpower some components IR Sensors If using a CB12 connecting block try a 78...

Page 10: ...ill indicate the supply is good but in some cases the supply can still be bad i e reads good when not plugged in but may not be able to handle the current load of the system 2 Verify Emitter 283M or 2...

Page 11: ...and verify the TB LED on the Receiver lights Xantech Corporation 13100 Telfair Avenue 2 F Sylmar CA 91342 Phone 818 362 0353 Fax 818 362 9506 Instructions 480 95 2006 Xantech Corporation This documen...