08905099B
-
4
-
ADVANCED WIRING CONFIGURATION
480-95 may also be used in conjunction with other Xantech IR Receivers by simply wiring in parallel
on a Connecting Block such as the 791-44 Amplified Block as shown in the figure below.
1. Connect all IR Receivers in parallel at the terminals of the connecting block as shown in the
figure below.
2. Plug in the 2.1mm Coaxial power plug of the 781RG (or 782) Power supply (not included) into
the jack labeled PWR on the 789-44CB.
Note: Up to 7 IR Receivers may be connected in parallel with a single 781RG power supply. If
more IR Receivers or any Keypads are required, check total current requirements and
increase power supply current rating accordingly; i.e. 782-00 – 1.2A Power Supply)
3. Plug in the Emitters 3.5mm mono mini plug (282, 284, 283 or 286 series) into the Emitter
Outputs on the 791-44.
120 V AC
(Unswitched)
782-00
Power Supply
490-00
Series
Micro Link
IR Receivers
3-Wire
Cable
IR OUT
GND
+12V
Red
Stripe
3-Wire
Cable
IR OUT
GND
+12V
480-85
Dinky Link
IR Receiver
Red
(or white)
Stripe
REMOTE ROOM 1
780-80
J-Box IR Receiver
7 Foot 3-Conductor
Cable with Quick
Connect Stereo
Mini Plug
490-30
Series
Micro Link
IR Receivers
REMOTE ROOM 2
REMOTE ROOM 3
REMOTE ROOM 4
GND
IR
OUT
+12V
3-Conductor
Room-to-
Room Cables
(Home Runs)
+12VDC
STATUS
GND
IR OUT
780-80
IR RECEIVER
®
Satellite
Receiver
VCR
AV
Receiver
CD
Changer
Tape
DecK
791-44
Amplified
Connecting Block
283M
Blink-IR
283M
Blink-IR
283M
Blink-IR
283M
Blink-IR
480-95
283M
Blink-IR
Mouse Emitter
+12 VDC
GND
EMITTERS
12
VDC
HIGH
IR
OUT
STATUS
IR IN
IR
RCVR
791-
44
AMPLIFIED
CONNECTING BLOCK
®
3-Wire
Cable
IR OUT
GND
+12V
Red
(or white)
Stripe