WIRING DIAGRAM

DALI

connect 

grounding

attach to cover 

(not shown)

DA DA

Gr

ound

– + IN

DA DA

OUT 

+

MOUNTING INSTRUCTIONS

MOVE IT 1.2     

RECESSED

XAL Inc.   150 Hawley Rd.   Oxford, CT 06478   T: +1 203.262.9990   www.xalusa.com

4

Summary of Contents for MOVE IT 1.2

Page 1: ...ales Service Hotline is available from Monday to Friday 8 AM 6 PM EST Hotline 1 203 262 9990 Email service xalusa com spackle knife drywall saw pencil drill screws screwdriver TOOLS REQUIRED not included POWER OFF POWER ON DON T TOUCH THE LED ATTENTION USE ESD GLOVES SIGN LEGEND Channel dimensions Power supply dimensions 1 38 1mm 1 28 7mm 3 82 6mm 2 50 8mm 1 25 4mm 2 7 15 ...

Page 2: ...WIRING DIAGRAMS LINE DIM CONTROL 0 10V NON DIM ZIGBEE DIM MOUNTING INSTRUCTIONS MOVE IT 1 2 RECESSED XAL Inc 150 Hawley Rd Oxford CT 06478 T 1 203 262 9990 www xalusa com 2 ...

Page 3: ...ED XAL Inc 150 Hawley Rd Oxford CT 06478 T 1 203 262 9990 www xalusa com 3 WIRING DIAGRAM LINE DIM CONTROL DUAL CHANNEL 0 10V DIMMING Channel 1 Channel 2 Two 0 10V Dimmers By others Three Way Primary wiring configuration Feeder Cable to track ...

Page 4: ...IRING DIAGRAM DALI connect grounding attach to cover not shown DA DA Ground IN DA DA OUT MOUNTING INSTRUCTIONS MOVE IT 1 2 RECESSED XAL Inc 150 Hawley Rd Oxford CT 06478 T 1 203 262 9990 www xalusa com 4 ...

Page 5: ...ance Turn OFF power source before installation 3 Insert blocking If single skip to step 5 4 Install linear connector onto first track 11 Insert X Connector optional Use screws to attach X connection 13 5 Screw track s to blocks through drywall If single track skip to step 9 6 Insert next track Repeat step 5 7 Use screws to secure connector again 8 Turn tentioning screw counter clockwise 10 9 Inser...

Page 6: ...0 80 50 30 20 240W 65 65 40 25 15 320W 50 50 30 18 11 LENGTH A see diagram drawing below DRIVER FEED MOVE IT TRACK MOVE IT TRACK LENGTH A Due to voltage drop and to fulfill EMC requirements total fixture power W must be between 60 95 of the driver s capacity Calcu lations based atmax capacity of the driver 14 Insert feeder into track 15 Connect feeder to converter box Please see wiring diagram on ...

Page 7: ...sseur XAL ne assume pas la garantie si cette norme ne se respecte pas ES La instalación la puesta en marcha y el mantenimiento sólo deben realizarse por personal especializado considerando esta guía de instalación y todas las normas y reglamentaciones vigentes Asegurarse de la aptitud eléctrica mecá en esta p ej Limpieza Esperar hasta que se enfríen la luminaria y la lámpara completamente Tener en...