background image

MOUNTING INSTRUCTIONS

MOVE IT 1.2     

RECESSED

XAL Inc.   150 Hawley Rd.   Oxford, CT 06478   T: +1 203.262.9990   www.xalusa.com

6

20. Installation complete

19 A. Snap inset(s) into track(s)

19 B. Place magnetic inset(s) into

         tracks

12 AWG  14 AWG  16 AWG  18 AWG  20 AWG 

60W

225'

225'

150'

80'

50'

100W

150'

150'

100'

60'

40'

150W

100'

100'

60'

40'

25'

185W

80'

80'

50'

30'

20'

240W

65'

65'

40'

25'

15'

320W

50'

50'

30'

18'

11'

LENGTH A

 

(see diagram drawing below)

 

DRIVER

FEED

MOVE IT TRACK

MOVE IT TRACK

LENGTH  A

Due to voltage drop and to 

fulfill EMC requirements, 

total fixture power [W] must 

be between 60% & 95% of 

the driver’s capacity. Calcu-

lations based atmax capacity 

of the driver.

14. Insert feeder into track

15. Connect feeder to converter box Please see wiring diagram

on page 2

16. Cover gaps and flange with

     spackle

17. Once dry, paint over spackle

18. Snap track 

      connector 

      into track

RED

 

+

 

BLACK

 

 

Summary of Contents for MOVE IT 1.2

Page 1: ...ales Service Hotline is available from Monday to Friday 8 AM 6 PM EST Hotline 1 203 262 9990 Email service xalusa com spackle knife drywall saw pencil drill screws screwdriver TOOLS REQUIRED not included POWER OFF POWER ON DON T TOUCH THE LED ATTENTION USE ESD GLOVES SIGN LEGEND Channel dimensions Power supply dimensions 1 38 1mm 1 28 7mm 3 82 6mm 2 50 8mm 1 25 4mm 2 7 15 ...

Page 2: ...WIRING DIAGRAMS LINE DIM CONTROL 0 10V NON DIM ZIGBEE DIM MOUNTING INSTRUCTIONS MOVE IT 1 2 RECESSED XAL Inc 150 Hawley Rd Oxford CT 06478 T 1 203 262 9990 www xalusa com 2 ...

Page 3: ...ED XAL Inc 150 Hawley Rd Oxford CT 06478 T 1 203 262 9990 www xalusa com 3 WIRING DIAGRAM LINE DIM CONTROL DUAL CHANNEL 0 10V DIMMING Channel 1 Channel 2 Two 0 10V Dimmers By others Three Way Primary wiring configuration Feeder Cable to track ...

Page 4: ...IRING DIAGRAM DALI connect grounding attach to cover not shown DA DA Ground IN DA DA OUT MOUNTING INSTRUCTIONS MOVE IT 1 2 RECESSED XAL Inc 150 Hawley Rd Oxford CT 06478 T 1 203 262 9990 www xalusa com 4 ...

Page 5: ...ance Turn OFF power source before installation 3 Insert blocking If single skip to step 5 4 Install linear connector onto first track 11 Insert X Connector optional Use screws to attach X connection 13 5 Screw track s to blocks through drywall If single track skip to step 9 6 Insert next track Repeat step 5 7 Use screws to secure connector again 8 Turn tentioning screw counter clockwise 10 9 Inser...

Page 6: ...0 80 50 30 20 240W 65 65 40 25 15 320W 50 50 30 18 11 LENGTH A see diagram drawing below DRIVER FEED MOVE IT TRACK MOVE IT TRACK LENGTH A Due to voltage drop and to fulfill EMC requirements total fixture power W must be between 60 95 of the driver s capacity Calcu lations based atmax capacity of the driver 14 Insert feeder into track 15 Connect feeder to converter box Please see wiring diagram on ...

Page 7: ...sseur XAL ne assume pas la garantie si cette norme ne se respecte pas ES La instalación la puesta en marcha y el mantenimiento sólo deben realizarse por personal especializado considerando esta guía de instalación y todas las normas y reglamentaciones vigentes Asegurarse de la aptitud eléctrica mecá en esta p ej Limpieza Esperar hasta que se enfríen la luminaria y la lámpara completamente Tener en...