XALR5 Liquid Tube Replacement:

1

2

3

4

5

6

·

Make sure to apply grease and avoid foreign matters.

·

Make sure the parts are in place and there is no obvious gap in between.

1.

 Inlet/Outlet Tube

2.

 Screw

3.

 Peristaltic Pump Cover

4.

 Synchroniser

5.

 Pump Tube

6.

 Pagoda-shaped Connector

Disassemble

Warning

1.

Drain the liquid in the tubes and unplug the inlet and outlet tubes of the peristaltic 
pump.

2.

Remove the screws that secure the peristaltic pump cover.

3.

Remove the peristaltic pump cover, synchronizer, damaged pump tube, and pagoda-
shaped connectors, and separate the connectors from the damaged pump tube.

A

ssemble

1.

Connect the pagoda-shaped connectors to the pump tube. Apply grease to the inner 
wall of the pump head and the rotor of the synchronizer synchronizer. 

2.

Bend the silicone tube around the synchronizer and press it into the pump head. 
Press the silicone tube down to the center of the rotor.

3.

Install the pagoda-shaped connectors, and put the peristaltic pump cover back in 
place and tighten the screws.

Summary of Contents for ALR5

Page 1: ...ALR5 Automatic Liquid Refiller Quick Start Guide Version 1 1 EN ...

Page 2: ......

Page 3: ...Support via email info xa com To Users Dear user thank you for choosing XAG products For safety reasons and the best experience possible XAG recommends that you read through the Quick Start Guide and Disclaimer in this document before attempting to use the ALR5 Automatic Liquid Refiller ...

Page 4: ...ease carefully check if it contains all the items listed below Please contact your dealer if there are any missing items Refiller 1 1 2 3 4 5 6 7 8 9 10 6 7 8 9 10 Discharge Port Compatible Buckles Left Right and Rear Inlet Tube Sieve Container Slot Base 1 2 3 4 5 Control Panel Status Indicator Inlet Tube USB Charging Port Pump Handle Power Adapter 1 USB To Type C Cable 1 ...

Page 5: ... secs of the last task the power indicator will flash for 8 secs and shutdown Pause PAUSE Button Pause Refilling Pumpout Pumpout Button Empty the Container Remarks If the Bluetooth connection between the Refiller and the liquid container is lost the device will stop after 20sec Half HALF Button Fill the container to HALF capacity Remarks ALR5 will stop refilling If the Bluetooth connection between...

Page 6: ... Half Pump out Pause ON OFF Powe r Level Batter y Malfu nction 1 Insert the Inlet tube into prepared container 2 Turn ON the ALR5 Refiller 3 Place the Liquid Container into the Container Slot the device will issue a buzzer DI when the container is inserted correctly 4 Turn ON the Liquid Container 5 On the control panel select the volume to refill ...

Page 7: ...en it starts operation and thus an alert is sent The float of the container is stuck or the inlet tube of the refiller is blocked and thus an alert is sent The refiller detects irregular rotational speed and thus an alert is sent The refiller has completed the operation The filler detects low power level The operation is suspended All indicators flash eight times and the buzzer beeps eight times b...

Page 8: ... icon Step 3 Select the Bluetooth name XALR5 Step 4 Click Upgrade It takes around 2 minutes to complete the upgrade Firmware Center Field Mapping Frequency Scanner Gallery Settings plant protection operation Recorder Container Toolkit System Settings Factory Testing Select the product to be upgraded XALR5 Searching for Refillers Next Step Upgrade Upgrade XALR5 XALR5 Connected Module Current Revisi...

Page 9: ... the screws that secure the peristaltic pump cover 3 Remove the peristaltic pump cover synchronizer damaged pump tube and pagoda shaped connectors and separate the connectors from the damaged pump tube Assemble 1 Connect the pagoda shaped connectors to the pump tube Apply grease to the inner wall of the pump head and the rotor of the synchronizer synchronizer 2 Bend the silicone tube around the sy...

Page 10: ...eep twice and the fault indicator will turn red 3 If the refiller is turned on when it is not connected to the container via Bluetooth the buzzer will beep three times and the fault indicator will turn red 4 If the float of the container is stuck or the flow rate of the refiller is too low the buzzer will beep four times and the fault indicator will turn red 5 If the rotational speed of the refill...

Page 11: ...ebsite the Manual Operation Manual online APP and other means without prior notice 1 Please read this document carefully before using this product This Disclaimer has an important impact on the safe use of the product and your legitimate rights and interests The use of the product shall be deemed as you have known understood acknowledged and accepted all terms and contents of this document 2 This ...

Page 12: ...illustrations photos methods and processes etc belongs to XAG Co Ltd and is protected by copyright law Without written authorization no individual or institution is allowed to reproduce extract translate distribute or otherwise reproduce or quote any content hereof This Manual is subject to upgrade without prior notice ...

Reviews: