XALR5 Liquid Tube Replacement:
1
2
3
4
5
6
·
Make sure to apply grease and avoid foreign matters.
·
Make sure the parts are in place and there is no obvious gap in between.
1.
Inlet/Outlet Tube
2.
Screw
3.
Peristaltic Pump Cover
4.
Synchroniser
5.
Pump Tube
6.
Pagoda-shaped Connector
Disassemble
Warning
1.
Drain the liquid in the tubes and unplug the inlet and outlet tubes of the peristaltic
pump.
2.
Remove the screws that secure the peristaltic pump cover.
3.
Remove the peristaltic pump cover, synchronizer, damaged pump tube, and pagoda-
shaped connectors, and separate the connectors from the damaged pump tube.
A
ssemble
1.
Connect the pagoda-shaped connectors to the pump tube. Apply grease to the inner
wall of the pump head and the rotor of the synchronizer synchronizer.
2.
Bend the silicone tube around the synchronizer and press it into the pump head.
Press the silicone tube down to the center of the rotor.
3.
Install the pagoda-shaped connectors, and put the peristaltic pump cover back in
place and tighten the screws.