background image

3

2

READ THIS FIRST

This  equipment  generates  and  uses  radio

frequency energy, and if not installed and used

properly,  that  is,  in  strict  accordance  with  the

manufacturers  instructions,  may  cause

interference to radio and television reception. It

has been type tested and found to comply with

the limits for remote control security devices in

accordance with the specifications in Sub-Parts

B  and  C  of  Part  15  of 

FCC  Rules

,  which  are

designed to provide reasonable protection against

such  interference  in  a  residential  installation.

However, there is no guarantee that interference

will not occur in a particular installation. If this

equipment does cause interference to radio or

television reception, which can be determined by

unplugging  the  equipment,  try  to  correct  the

interference  by  one  or  more  of  the  following

measures.

Reorient  the  antenna  of  the  radio/TV

experiencing the interference.

Relocate  the  console  with  respect  to  the

radio/TV.

Move the console away from the radio/TV.

Plug the console into an outlet on a different

electrical circuit from the radio/TV experiencing

the interference.

If necessary, consult your local X10 Dealer for

additional suggestions.

Your console’s telephone dialer is designed to

conform  to  federal  regulations,  and  you  can

connect it to most telephone lines. However, each

telephone or telephone device that you connect

to  the  telephone  line  draws  power  from  the

telephone line. We refer to this power draw as the

device’s ringer equivalence number, or REN.

If you use more than one telephone or other device

on the line, add up all the RENs. If the total is

more than five, your telephones might not ring. In

rural  areas,  a  total  REN  of  three  might  impair

ringer operation. If ringer operation is impaired,

remove one of the devices from the line.

Note:

 You must not connect your console to:

Coin-operated systems

Party-line systems

Most electronic key telephone systems

Your console’s telephone dialer complies with Part

68 of 

FCC Rules

. You must, upon request, provide

the FCC registration number and the REN to your

telephone company. Both numbers are shown on

the bottom of the console.

The telephone portion of your security console

has  been  tested  and  found  to  comply  with  all

applicable UL and FCC standards.

In the unlikely event that your console causes

problems on the telephone line, the telephone

company  can  disconnect  your  service.  The

telephone  company  attempts  to  notify  you  in

advance. If advance notice is not practical, the

telephone  company  notifies  you  as  soon  as

possible and advises you of your right to file a

complaint with the FCC.

Also, the telephone company can make changes

to its lines, equipment, operations, or procedures

that could affect the operation of this console. The

telephone company notifies you of these changes

in advance, so you can take the necessary steps

to prevent interruption of your telephone service.

Note: 

The security functions of this system have

not been tested by Underwriters Laboratories.

CONTENTS

INTRODUCTION ................................................................................................... 4

SETTING UP THE CONSOLE .............................................................................. 5

SETTING UP REMOTE CONTROLS ................................................................... 8

SETTING UP DOOR/WINDOW SENSORS ......................................................... 9

SETTING UP MOTION SENSORS .....................................................................12

SETTING UP REMOTE MODULES ................................................................... 15

SETTING UP FOR THE MONITORING STATION .............................................. 17

USING THE SYSTEM .........................................................................................18

TURNING LIGHTS ON AND OFF REMOTELY .................................................. 23

REPLACING BATTERIES ...................................................................................24

TO CLEAR ALL SENSORS AND REMOTES FROM THE CONSOLE ............... 25

TROUBLESHOOTING ........................................................................................26

All manuals and user guides at all-guides.com

Summary of Contents for Monitor Plus DC8700P

Page 1: ...NTRY DOOR WINDOW SENSOR MOTION DETECTOR Lamp Module A I E M O C G K 1 9 5 13 15 3 7 11 UNIT HOUSE BATTERY ARM DISARM LIGHTS ON LIGHTS OFF PANIC Monitored Security System Model DC8700P Monitor Plus ARM AC POWER MONITOR BATTERY LOW ZONES 1 9 2 10 3 4 5 6 7 8 11 12 13 14 15 16 BYPASS ON LIGHTS OFF ZONES 9 16 PANIC AWAY ARM HOME All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...more than five your telephones might not ring In rural areas a total REN of three might impair ringer operation If ringer operation is impaired remove one of the devices from the line Note You must not connect your console to Coin operated systems Party line systems Most electronic key telephone systems Your console s telephone dialer complies with Part 68 ofFCC Rules You must upon request provide...

Page 3: ...ital Communicator Calls the monitoring station in the event of a break in Fully expandable You can protect up to 16 zones with your security system plus you can control lights and appliances by Remote Control to start a complete home automation system Panic Alarm Lets you sound the alarm without calling the monitoring station Automatic lighting control When the Monitor Plus Security System is arme...

Page 4: ...plugged into the telephone device If you already have a phone plugged into the jack use the included T adapter to plug the console and telephone into the same jack If your telephone wiring does not have a modular jack you can Update the wiring yourself Most good electrical stores sell adapters to convert older wiring methods to modular wiring Have the telephone company update the wiring for you No...

Page 5: ... RUN2 Note If you do not hear a tone press the CODE button located on the front under the label with a pencil then reinstall the remote as described above PANIC PANIC ARM DIS HOME ARM ARM DIS AWAY ARM SECURITY LIGHT ON OFF A I E M O C G K INSTANT DELAY BRIGHT DIM ENTRY 4 Set the console s slide switch back to RUN1 or RUN2 5 To set up additional key chain remote controls up to eight repeat steps 1 ...

Page 6: ... 2 Open the door or window The light on the sensor blinks the console chimes and the zone light for the sensor lights If the light on the sensor does not blink and the console doesn t chime check that the Door Window Sensor magnet and switch are correctly aligned with the arrows facing each other Typical Door Window Sensor mounting methods 4 Press TEST again The Console s next unused zone indicato...

Page 7: ...ensor just like you initialize Door Window Sensors Each Motion Sensor will be assigned to one of the 16 zones 1 Install four AA alkaline batteries in the battery compartment on the front of the Motion Sensor batteries sold separately Note Place the Motion Sensor face down so that it doesn t see anything during installation Otherwise if it is sees motion it might be installed twice causing erroneou...

Page 8: ...llow the installation instructions included with the Wall Switch Module sold separately Set the House Code and Unit Code to A 13 or other codes on request from the monitoring station see page 18 if you want the lamp to flash during an alarm Remote Switch 1 9 5 13 A I E M All types of Motion Sensors sense motion by detecting a change in temperature Therefore to help prevent false alarms do not plac...

Page 9: ...the enclosed monitoring agreement and mail or fax it to ORCA Monitoring Services Call ORCA Monitoring Services at 1 800 FOR ORCA 1 800 367 6722 and follow the instructions to have your system initialized Note Although you can register your system as soon as it has been installed the Monitoring Station will not respond to alarm calls until the signed monitoring agreement has been received and you h...

Page 10: ...TEM Calling Customer Service After you have registered your system you can easily call the customer service center if you need help or to change any of the default options as follows Set the Base Console slide switch to RUN1 or RUN2 Press the MONITOR button The console automatically dials the customer service number Pick up the handset of a phone connected to the same line as the console Alternati...

Page 11: ...lay can be changed by the service station 3 PressDISARM to stop the siren The lights remain on Self checking system All Door Window Sensors and Motion Sensors report in to the Console every 90 minutes If the Console does not receive a signal from the sensor within four hours it reports a problem with that sensor by slowly flashing the appropriate zone indicator If you try to arm the system with a ...

Page 12: ... alarm but will not call the monitoring station unless you arm the system first This option can be changed by the service station To trigger the panic alarm Press PANIC on the Security Home Automation Remote Control or press ARM and DISARM together on the Keychain Remote PressDISARM to cancel the alarm Trouble Alarm If you hear a repetitive trouble alarm when you try to arm the system there is a p...

Page 13: ...A alkaline batteries For the Security Home Automation Remote use four AAA alkaline batteries After replacing batteries the following steps are necessary to determine that the console still recognizes the remote control 1 Place the console slide switch under the SETUP flip door to RUN2 2 PressARM on the Remote Control If the system arms the Console recognized the Remote Control and no further actio...

Page 14: ...dicator on the Remote Control comes on when you press a button Replace batteries and reinstall remote if necessary Lights will not turn on or off from the LIGHT ON or LIGHT OFF buttons on the Remote Control TROUBLESHOOTING PROBLEM SOLUTION Check that the slide switch under the SETUP flip door is set to RUN1 or RUN2 Check that the red indicator on the Remote Control turns on when you press ARM Repl...

Page 15: ...ait a few seconds then replace the batteries Press CODE then press ARM again SOLUTION PROBLEM You open a door or window and the alarm does not trip Check that the system is armed Be sure the slide switch under the SETUP flip door is in the RUN1 or RUN2 position Check to see if the alarm trips when you pressTEST on the Door Window Sensor If the alarm does not trip when you press TEST check that the...

Page 16: ...rn the zone indicator off and stop the armed indicator from flashing press the LIGHT ON or LIGHT OFF button on the remote control If a zone indicator is not on the violated zone will have been one of the second eight zones Press BYPASS to see which zone was tripped If thePOWERHORN does not trip when the alarm trips Be sure you set the Housecode on thePOWERHORN to the same letter and number as down...

Page 17: ...Y DOES NOT EXTEND TO ANY X10 PRODUCTS WHICH HAVE BEEN SUBJECT TO MISUSE NEGLECT ACCIDENT INCORRECT WIRING OR TO USE IN VIOLATION OF OPERATING INSTRUCTIONS FURNISHED BY US NOR EXTEND TO ANY UNITS ALTERED OR REPAIRED FOR WARRANTY DEFECT BY ANYONE OTHER THAN X10 THIS WARRANTY DOES NOT COVER ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND NO REPR...

Reviews: