background image

Supervised Security System

With Digital Central Station Communicator

1st Draft

PANIC     PANIC

ARM            DIS-
HOME         ARM

ARM            DIS-
AWAY        ARM

SECURITY

LIGHT

ON          OFF

A

I

E

M

O

C

G

K

INSTANT

DELAY

BRIGHT      DIM

ENTRY

DOOR/WINDOW SENSOR

MOTION DETECTOR

Lamp Module

A

I

E

M

O

C

G

K

1

9

5

13

15

3

7

11

UNIT

HOUSE

BATTERY

ARM

DISARM

LIGHTS
ON

LIGHTS
OFF

PANIC

Monitored Security System, Model DC8700P

Monitor Plus

ARM

AC POWER

MONITOR

BATTERY LOW

ZONES

1

9

2

10

3

4

5

6

7

8

11

12

13

14

15

16

BYPASS

ON  -  LIGHTS  -  OFF

ZONES 9-16

PANIC

AWAY  -  ARM  -  HOME

®

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for Monitor Plus DC8700P

Page 1: ...NTRY DOOR WINDOW SENSOR MOTION DETECTOR Lamp Module A I E M O C G K 1 9 5 13 15 3 7 11 UNIT HOUSE BATTERY ARM DISARM LIGHTS ON LIGHTS OFF PANIC Monitored Security System Model DC8700P Monitor Plus ARM AC POWER MONITOR BATTERY LOW ZONES 1 9 2 10 3 4 5 6 7 8 11 12 13 14 15 16 BYPASS ON LIGHTS OFF ZONES 9 16 PANIC AWAY ARM HOME All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...more than five your telephones might not ring In rural areas a total REN of three might impair ringer operation If ringer operation is impaired remove one of the devices from the line Note You must not connect your console to Coin operated systems Party line systems Most electronic key telephone systems Your console s telephone dialer complies with Part 68 ofFCC Rules You must upon request provide...

Page 3: ...ital Communicator Calls the monitoring station in the event of a break in Fully expandable You can protect up to 16 zones with your security system plus you can control lights and appliances by Remote Control to start a complete home automation system Panic Alarm Lets you sound the alarm without calling the monitoring station Automatic lighting control When the Monitor Plus Security System is arme...

Page 4: ...plugged into the telephone device If you already have a phone plugged into the jack use the included T adapter to plug the console and telephone into the same jack If your telephone wiring does not have a modular jack you can Update the wiring yourself Most good electrical stores sell adapters to convert older wiring methods to modular wiring Have the telephone company update the wiring for you No...

Page 5: ... RUN2 Note If you do not hear a tone press the CODE button located on the front under the label with a pencil then reinstall the remote as described above PANIC PANIC ARM DIS HOME ARM ARM DIS AWAY ARM SECURITY LIGHT ON OFF A I E M O C G K INSTANT DELAY BRIGHT DIM ENTRY 4 Set the console s slide switch back to RUN1 or RUN2 5 To set up additional key chain remote controls up to eight repeat steps 1 ...

Page 6: ... 2 Open the door or window The light on the sensor blinks the console chimes and the zone light for the sensor lights If the light on the sensor does not blink and the console doesn t chime check that the Door Window Sensor magnet and switch are correctly aligned with the arrows facing each other Typical Door Window Sensor mounting methods 4 Press TEST again The Console s next unused zone indicato...

Page 7: ...ensor just like you initialize Door Window Sensors Each Motion Sensor will be assigned to one of the 16 zones 1 Install four AA alkaline batteries in the battery compartment on the front of the Motion Sensor batteries sold separately Note Place the Motion Sensor face down so that it doesn t see anything during installation Otherwise if it is sees motion it might be installed twice causing erroneou...

Page 8: ...llow the installation instructions included with the Wall Switch Module sold separately Set the House Code and Unit Code to A 13 or other codes on request from the monitoring station see page 18 if you want the lamp to flash during an alarm Remote Switch 1 9 5 13 A I E M All types of Motion Sensors sense motion by detecting a change in temperature Therefore to help prevent false alarms do not plac...

Page 9: ...the enclosed monitoring agreement and mail or fax it to ORCA Monitoring Services Call ORCA Monitoring Services at 1 800 FOR ORCA 1 800 367 6722 and follow the instructions to have your system initialized Note Although you can register your system as soon as it has been installed the Monitoring Station will not respond to alarm calls until the signed monitoring agreement has been received and you h...

Page 10: ...TEM Calling Customer Service After you have registered your system you can easily call the customer service center if you need help or to change any of the default options as follows Set the Base Console slide switch to RUN1 or RUN2 Press the MONITOR button The console automatically dials the customer service number Pick up the handset of a phone connected to the same line as the console Alternati...

Page 11: ...lay can be changed by the service station 3 PressDISARM to stop the siren The lights remain on Self checking system All Door Window Sensors and Motion Sensors report in to the Console every 90 minutes If the Console does not receive a signal from the sensor within four hours it reports a problem with that sensor by slowly flashing the appropriate zone indicator If you try to arm the system with a ...

Page 12: ... alarm but will not call the monitoring station unless you arm the system first This option can be changed by the service station To trigger the panic alarm Press PANIC on the Security Home Automation Remote Control or press ARM and DISARM together on the Keychain Remote PressDISARM to cancel the alarm Trouble Alarm If you hear a repetitive trouble alarm when you try to arm the system there is a p...

Page 13: ...A alkaline batteries For the Security Home Automation Remote use four AAA alkaline batteries After replacing batteries the following steps are necessary to determine that the console still recognizes the remote control 1 Place the console slide switch under the SETUP flip door to RUN2 2 PressARM on the Remote Control If the system arms the Console recognized the Remote Control and no further actio...

Page 14: ...dicator on the Remote Control comes on when you press a button Replace batteries and reinstall remote if necessary Lights will not turn on or off from the LIGHT ON or LIGHT OFF buttons on the Remote Control TROUBLESHOOTING PROBLEM SOLUTION Check that the slide switch under the SETUP flip door is set to RUN1 or RUN2 Check that the red indicator on the Remote Control turns on when you press ARM Repl...

Page 15: ...ait a few seconds then replace the batteries Press CODE then press ARM again SOLUTION PROBLEM You open a door or window and the alarm does not trip Check that the system is armed Be sure the slide switch under the SETUP flip door is in the RUN1 or RUN2 position Check to see if the alarm trips when you pressTEST on the Door Window Sensor If the alarm does not trip when you press TEST check that the...

Page 16: ...rn the zone indicator off and stop the armed indicator from flashing press the LIGHT ON or LIGHT OFF button on the remote control If a zone indicator is not on the violated zone will have been one of the second eight zones Press BYPASS to see which zone was tripped If thePOWERHORN does not trip when the alarm trips Be sure you set the Housecode on thePOWERHORN to the same letter and number as down...

Page 17: ...Y DOES NOT EXTEND TO ANY X10 PRODUCTS WHICH HAVE BEEN SUBJECT TO MISUSE NEGLECT ACCIDENT INCORRECT WIRING OR TO USE IN VIOLATION OF OPERATING INSTRUCTIONS FURNISHED BY US NOR EXTEND TO ANY UNITS ALTERED OR REPAIRED FOR WARRANTY DEFECT BY ANYONE OTHER THAN X10 THIS WARRANTY DOES NOT COVER ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND NO REPR...