- 6 -
iii. Adjust the temperature to the desired value using the Air Temp
Control knob located in the upper right hand corner of the front
panel.
iv. Adjust the air flow to the desired amount using the Air Set knob
located in the center right of the front panel, directly beneath
the Air Temp set knob.
NOTE: Please be sure to use an air setting of above 4 when
using hot air temperatures of over 300°C. Failure to do so
could result in overheating of the hot air heating element and
cause premature failure.
USER INTERFACE
1. 4040 Unit
2. Hot Air Gun Connection
3. Soldering Iron Connection
4. Power Switch
a. Soldering Iron
b. Hot Air Gun
5. Temperature Display
a. Soldering Iron
b. Hot Air Gun
6. Temperature Control Knob
a. Soldering Iron
b. Hot Air Gun
7. Air Flow Adjustment Knob
8. Hot Air Heating indicator LED
OPERATING GUIDELINES
1. Before turning on the unit, ensure that the hot air gun is in the
holster and the soldering iron is connected properly.
2. Ensure there are no obstructions or blockages in the hot air gun
and/or attachments.
3. After using the hot air gun, place it back into the holster and
allow the unit to initiate the cool down procedure until the display
reads “---“, then turn off the power.
4. When using the small nozzle attachment for the hot air gun, set
the airflow to the maximum value to keep the hot air heating