- 8 -
HOT AIR GUN AUTO COOL DOWN / STANDBY FUNCTION
When the hot air gun is placed in the vertical position in the upright
tower holder, it will automatically go into Auto Cool Down / Standby
mode. When the hot air gun is initially returned to the holder, the
air flow may increase noticeably while the hot air gun is cooling
down and going into standby mode. This is a safety feature built
into the unit.
TEMPERATURE CONVERSION
While the unit is on, quickly press the Set button in the middle of
the unit. The display will toggle between °C and °F (displayed on
the left side of the screen).
MUTE / UNMUTE FUNCTION
The unit beeps when the buttons on the unit are engaged.
Press and hold the Set button. The screen will show “SPH ON” and
will audibly beep when the unit is Unmuted.
To Mute the unit, press and hold the Set button. The screen will
show “SPH OF” and there will be no audible noise when buttons
are pressed.
SETTING MEMORY PRESETS
1. When the temperature and air flow are set, press and hold any one
of the four memory preset buttons for approximately 5 seconds.
2. The left display on the screen will display CH”X” (X indicating the
chosen channel number), indicating that the chosen setting are
now programmed into that memory preset.
3. To quickly select any of the presets, briefly touch the preset while
the hot air gun is in use and it will change to the saved settings.
4. To re-program one of the presets, set the temperature and air flow
parameters to the new settings and then press and hold the preset
to be re-programmed for approximately 5 seconds.
CALIBRATION FUNCTION
When is it time to Calibrate your Hot Air Station?
All X-Tronic Stations come with a high quality heating element
in the hot air gun that is calibrated to within ±1.8°F/1.0°C of the
temperature that is shown on the LED Display. While calibrating
to the exact temperature is the ultimate goal, this heating element
and nozzle design is as close as can be achieved with this
technology.