background image

- 1 -

PLEASE READ THESE INSTRUCTIONS BEFORE USING THE NEW 

X-TRONIC MODEL #4020-PRO-X HOT AIR REWORK STATION

TABLE OF CONTENTS

Product Specifications......................................................2

Package Contents .............................................................2

Safety Precautions ............................................................3 

Unit Diagram ......................................................................4

Initial Set-up .......................................................................5

Features..............................................................................7

Quick Change Nozzle Rack ............................................7
Auto Cool Down / Standby Mode ....................................8
Celsius / Fahrenheit Conversion .....................................8
Mute/Unmute Function ....................................................8
Memory Preset Channels ................................................8 
Calibration Function ........................................................8

Maintenance .....................................................................10

Replacing the Heating Element .....................................10

Troubleshooting ..............................................................11

Warranty ...........................................................................12

Contact Information ........................................................14

Summary of Contents for 4020-PRO-X

Page 1: ......

Page 2: ......

Page 3: ...2 Package Contents 2 Safety Precautions 3 Unit Diagram 4 Initial Set up 5 Features 7 Quick Change Nozzle Rack 7 Auto Cool Down Standby Mode 8 Celsius Fahrenheit Conversion 8 Mute Unmute Function 8 Memory Preset Channels 8 Calibration Function 8 Maintenance 10 Replacing the Heating Element 10 Troubleshooting 11 Warranty 12 Contact Information 14 ...

Page 4: ...dity 35 45 Airflow Type Brushless DC Vortex Blower Airflow Velocity 3 4 M S Air Volume 55 L Min Programmable Air Flow 1 120 Temperature Range 212 F 932 F 100 C 500 C Temperature Stability 1 C Cable Length Material 33 2 in Silicone Noise 70dB PACKAGE CONTENTS 1000 Watt Main Power Unit Deluxe Upright Tower Hot Air Gun Holder 1000 Watt Hot Air Gun Blue Sponge Patented Quick Change Nozzle Holder attac...

Page 5: ... serious burns instantly 5 Always turn the power off unplug the unit and let it fully cool down before attempting to replace any parts nozzle heating element etc 6 Use only genuine replacement parts for this unit 7 Do not use the unit for any application other than hot air rework 8 Do not modify the unit in any way 9 When replacing consumable parts only use approved manufacturer parts 10 Do not ge...

Page 6: ...Display 3 Set Temperature Display 4 Patented Quick Change Nozzle Rack Nozzles 5 Temperature Adjustment Buttons 6 Power Switch 7 4 Memory Preset Buttons 8 Function Set Button 9 Hot Air Gun Cord Receptical Hard wired 10 Air Flow Adjustment Buttons 11 Upright Tower Hot Air Gun Holder 12 Hot Air Gun ...

Page 7: ...temperature All three of the LED displays will show indicating that the unit is in Standby Mode 5 Push the Hot Air Temperature Adjustment Buttons or on the left side of the unit to set the hot air gun temperature The temperature range is 212 F 932 F 100 C 500 C 6 Push the Air Flow Adjustment Buttons or on the right side of the unit to set the hot air gun temperature The air flow range is 1 120 CAU...

Page 8: ...the hot air gun automatically goes into Auto Cool Down Standby mode This allows the hot air gun to cool down quickly and efficiently This is a safety feature built into the unit 9 When the hot air gun is removed again from the holder it will start blowing air and ramp up to the programmed temperature and air speed quickly 10 When the work is completed return the hot air gun to the vertical positio...

Page 9: ... Figure 2 below 3 The nozzle is then secured on the hot air gun and ready to use See Figure 3 below Figure 1 Figure 2 Figure 3 To Remove a Nozzle 1 Choose an open nozzle space on the Quick Change Nozzle Rack See Figure 4 below 2 Placing the nozzle tip into the opening tilt the nozzle so that the 3mm of space between the gun and the nozzle are against the fingers of the rack then use the rack to pu...

Page 10: ...e when buttons are pressed SETTING MEMORY PRESETS 1 When the temperature and air flow are set press and hold any one of the four memory preset buttons for approximately 5 seconds 2 The left display on the screen will display CH X X indicating the chosen channel number indicating that the chosen setting are now programmed into that memory preset 3 To quickly select any of the presets briefly touch ...

Page 11: ...he temperature of the unit stabilizes measure the heat of the hot air using a high quality and well calibrated hot air tester or an infrared thermometer If using the infrared thermometer aim it approximately three inches away from the end of the hot air gun If the temperature shown on the unit s display does not reflect the temperature shown on the tester the unit can be calibrated 1 Ensure the un...

Page 12: ...le 3 Unscrew both of the screws at the base of the handle and separate the two handle sides 4 Pull the heating element out of the Mica Paper and Discharge Tube being careful not to disconnect grounding wire 5 Unscrew the two screws holding the circuit board in place 6 Desolder the four wires to the heating element Please take note of the location of the 4 wires thickness color for installation of ...

Page 13: ...eep Mode S E Error The heating element may need to be replaced Contact X Tronic International for technical assistance Contact information on back of manual HEA Error Issue with the heater The heating element may need to be replaced Contact X Tronic International for technical assistance Contact information on back of manual TMP Error Issue with the sensor Contact X Tronic International for techni...

Page 14: ... at 2159 Magnum Circle Lincoln Nebraska 68522 we extend this limited warranty only to the consumer who originally purchased the product in the United States the District of Columbia or Canada you It does not extend to a any subsequent owner or other transferee of the product b any product shipped outside of the United States the District of Columbia or Canada or c anyone who may have purchased it ...

Page 15: ...TY With respect to any defective product during the Initial Warranty Period we will in our sole discretion either a replace such product or the defective part free of charge or b refund the purchase price of such product With respect to any defective product during the Remaining Warranty Period we will repair such product free of charge and provide a full service inspection of your product You wil...

Page 16: ...our NEW Product Seal prior to shipment Our goal is to ensure Quality Completeness and Satisfaction for your order For Any Questions Problems or Compliments please call or email us If you would like to shop for other X Tronic International Products Please visit our website www XTronicUSA com Toll Free 844 861 4762 Info XTronicUSA com Our Business Hours are Monday Thursday 8am 4pm CST Friday 8am Noo...