![X-Trax X-10 Installation Manual Download Page 4](http://html2.mh-extra.com/html/x-trax/x-10/x-10_installation-manual_3059554004.webp)
4. Status LED and wiring description
Device status LED:
GSM LED - Blue
Status
Description
Off
Modem Off, GSM network not available,
modem in “sleep mode”, SIM card not inserted
or SIM PIN code enabled
Blinking
10 x (180ms On / 350ms Off)
Device restarting
Blinking
100ms On / 2sec Off
GSM network authentication in progress
Blinking
2 x 100ms On / 2sec Off
Connected to GPRS Server
Solid On
FPT download in progress
GPS LED - Green
Status
Description
Off
GPS receiver Off
Blinking
100ms On / 2sec Off
Invalid GPS fix or GPS receiver in “sleep
mode”
Blinking
2 x 100ms On / 2sec Off
Valid GPS fix
Solid On
Firmware upgrade by FPT in progress
Attention:
Please remove SIM Pin code before
using
Attention:
Please insert the SIM card into the
reader before powering up the device, respecting
the right side
5. Quick start
1- After inserting the SIM card, please turn ON the device by connecting Red
1-
wire (Positive) and Black wire (Negative) to main power supply. Please
1-
connect also White wire (Input 1) to ACC signal (+15) in order to maintain
1-
the device always On during the testing procedure. When the device is
1-
successfully connected to power supply both
blue
and
green LED
start
1-
blinking.
2- Please wait for few seconds till the modem will successfully authenticate to
1-
GSM network. When the GPRS connection is established with the Server
1-
blue LED
is blinking “2 x 100ms On / 2sec Off”.
3- In order to get the first GPS valid fix, it’s necessary to place the device in a
1-
good place (better in open sky condition) avoiding any metal surface
1-
obstructing it. When GPS is fixed
green LED
is blinking “2 x 100ms On /
1-
2sec Off”.
4- By SMS is possible to enable up to 2 user SMS numbers and assign a name
1-
to the device (max 12 characters).
1-
The SMS format must be:
#CFG*
Cell.1
*
Cell.2
*
Name
#
1-
Example of SMS message to enable one single user SMS number and assign
1-
a device name:
#CFG*
+391234567890
**
X10
#
5- After user SMS numbers have been successfully enabled then it is possible
1-
to manage a suite of SMS functions by remote, such as query the device
1-
position, enable/disable predefined output.
1-
Send
XPOS
-
SMS string to query the position.
1-
Send
XON
SMS string to enable the predefined output, and send
XOFF
to
1-
disable it.
1-
Only authorized SMS numbers by #CFG self-setting procedure (please refer
1-
to point No.4) or by Control Room remote settings are able to manage SMS
1-
functions (please refer to point No.5).
Attention:
For better using and reliability this device must be pretested from
authorized Control Room.
SIM Card reader