![x-sense Link SC06-W User Manual Download Page 3](http://html.mh-extra.com/html/x-sense/link-sc06-w/link-sc06-w_user-manual_880098003.webp)
Power Supply
10-year sealed lithium battery
Sensor Type
Smoke: Photoelectric
CO: Electrochemical
Product Lifespan
10 years
Safety Standard
UL217 and UL2034
CO Sensitivity
70 ppm for 60
–
240 minutes
150 ppm for 10
–
50 minutes
400 ppm for 4
–
15 minutes
Operating Temperature
40-100°F (4.4
–
37.8°C)
Operating Relative Humidity
10%
–
85% RH (non-condensing)
Alarm Loudness
≥
85 dB at 10 ft (3 m) @ 3.2 ± 0.3 kHz pulsing alarm
Silence Duration
≤ 9 minutes
Operating Frequency
915 MHz
Maximum Number of
Interconnected Units
24 wireless units (only compatible with X-Sense
wireless alarms)
Transmission Range
Over 820 ft (250 m) in open air
NOTES:
1.
Battery life is calculated on the current ratings in the standby mode with weekly
testings. If its operation mode changes to an alarming condition, the battery life will be
decreased accordingly.
2. This alarm functions between 40-100°F (4.4-37.8°C). Prolonged exposure to lower
or higher temperatures can reduce battery life and affect device performance. We do
not recommend operating the device beyond its temperature range.