Wireless Interlinked Combination Smoke and Carbon Monoxide Alarm

 

10-Year Sealed Battery Operated 

Model: SC06-W/SC07-W 

 

 

User Manual

 

 
 

 

Summary of Contents for Link SC06-W

Page 1: ...Wireless Interlinked Combination Smoke and Carbon Monoxide Alarm 10 Year Sealed Battery Operated Model SC06 W SC07 W User Manual ...

Page 2: ...s or bedding Carbon monoxide CO is odorless tasteless and invisible it s a silent killer Using electrochemical sensing technology this unit can detect increased levels of carbon monoxide early protecting your family from the dangers of carbon monoxide The installation of the apparatus should not be used as a substitute for proper installation use and maintenance of fuel burning appliances includin...

Page 3: ...n 9 minutes Operating Frequency 915 MHz Maximum Number of Interconnected Units 24 wireless units only compatible with X Sense wireless alarms Transmission Range Over 820 ft 250 m in open air NOTES 1 Battery life is calculated on the current ratings in the standby mode with weekly testings If its operation mode changes to an alarming condition the battery life will be decreased accordingly 2 This a...

Page 4: ... OR DROP THE ALARM DO NOT OPEN OR TAMPER WITH THE ALARM AS THIS COULD CAUSE MALFUNCTION LED Indicator Red Green Yellow Buzzer Test Silence Button LCD Display Test Silence Button SC06 W The Test Silence button is used to test the unit s electronics and to silence the unit during an alarm When testing the alarm weekly press and hold the test button until ...

Page 5: ...ll continue to alarm until the smoke concentration decreases to a safe low level Otherwise the alarm will enter the normal mode after 9 minutes CO Silence Mode Press the test button during an alarm to have the unit enter silence mode If the CO density still exceeds the alarm threshold the unit will re enter alarm state Otherwise the unit will exit the silence mode after 9 minutes and resume normal...

Page 6: ...the end of life signal cannot be silenced CO Alarm Levels This X Sensecombinationsmoke carbonmonoxide alarm is programmed to sound an alarm at the following CO concentrations within the time periods listed 70 ppm for 60 240 minutes 150 ppm for 10 50 minutes and 400 ppm for 4 15 minutes SC06 W When CO is detected and the alarm sounds the LED indicator will flash red and the alarm will issue 4 short...

Page 7: ...rent working modes and states are shown in the below table SC06 W Mode LED Indicator Audible Alarm Remarks Powering On Runs through 8 cycles yellow green red in sequence 1 quick beep Make sure the alarm is properly attached to the mounting bracket Standby Mode Flashes green once every 60 seconds None None Unit detects smoke and initiates an alarm Flashesred3 times every 4 seconds 3 long beeps ever...

Page 8: ...ected smoke and initiated an alarm The LED indicator flashes green once every second for 5 seconds None Alarm cancellation when the smoke concentration level drops below the alarm threshold the alarm signal will stop Then the alarm goes back to the standby mode Unit detected CO and initiated an alarm The LED indicator flashes green once every second for 5 seconds None Alarm cancellation when the C...

Page 9: ...g silence mode Low Battery Flashes yellow once every 60 seconds One beep every 60 seconds Replace the unitimmediately Fault Flashes yellow 2 times every 60 seconds 2 beeps every 60 seconds Please clean youralarm and see if it is working normally If the unit has malfunctioned it must be replaced immediately End of Life Flashes yellow 3 times every 60 seconds 3 beeps every 60 seconds Replace the uni...

Page 10: ...ed by the initiating unit in the network Please find the initiating unit and take action The LEDflashes red4 times then the green LED flashes once every 5 8 seconds 4quick beeps repeating every 5 8 seconds Dangerous CO concentration is detected by the initiating unit and has reached the alarm status Please find the initiating unit and take action Unit detects CO alarm not initiated A CO concentrat...

Page 11: ...interconnected units The LED indicator flashes red rapidly Continuous beeping until you release the Test Silence button Initiatingalarm Hold down the Test Silence button on one unit in the network The LEDflashes red and green sequentially Other interconnected alarms in the network Silence Mode Flashesred3 times every 4 seconds None Smoke silence mode After 9 minutes the unit will exit silence mode...

Page 12: ...larms wirelessinterlinked carbon monoxide alarms and wirelessinterlinked smoke and carbon monoxide alarms This model is designed to be wirelessly interlinked with other X Sense Link alarms but is not designed to communicate with wirelessinterlinked alarms from other manufacturers A maximum of 24 X Sense safety devices may be interconnected in a multiple station arrangement The interconnect system ...

Page 13: ...ccessful and an interconnected group is created both units will beep once and automatically exit the interconnection mode At this point both units will only flash once 60 seconds indicating they are in normal standby mode 4 If you want to connect a third alarm to this group first activate a new device according to its operating instructions and then quickly press the test silence button on either ...

Page 14: ... can only be interconnected with other X Sense Link wireless interlinked alarms How to Disconnect Press the test silence button 4times the alarmwill beep once Then hold down the button until it beeps once more to disconnect After disconnecting it can be reconnected to the same network or added to a new network NOTE The X Sense Link wirelessinterlinked alarms in one multi pack have already been int...

Page 15: ...alarm are triggered in the network at the same time the alarm signal of the smoke alarm will take priority over that of the CO alarm This alarm has a relay function that extends the wireless interconnected network for wide detection coverage Alarm Test Be sure to test your alarms when you turn them on for the first time or when the group configuration has changed In addition to the weekly tests yo...

Page 16: ...GERS WARNINGS AND CAUTIONS ALERT YOU TO IMPORTANT OPERATING INSTRUCTIONS OR TO POTENTIALLY HAZARDOUS SITUATIONS PAY SPECIAL ATTENTION TO THESE SITUATIONS 2 THIS COMBINATION SMOKE CARBON MONOXIDE ALARM IS ONLY APPROVED FOR HOME USE 3 THIS CARBON MONOXIDE ALARM IS DESIGNED TO DETECT CARBON MONOXIDE FROM ANY SOURCE OF COMBUSTION 4 CONSTANT EXPOSURES TO HIGH OR LOW HUMIDITY MAY REDUCE BATTERY LIFE 5 S...

Page 17: ...URE CO LEVELS IN COMPLIANCE WITH OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION OSHA COMMERCIAL OR INDUSTRIAL STANDARDS INDIVIDUALS WITH MEDICAL CONDITIONS THAT MAY MAKE THEM MORE SENSITIVE TO CARBON MONOXIDE MAY CONSIDER USING WARNING DEVICES WHICH PROVIDE AUDIBLE AND VISUAL SIGNALS FOR CARBON MONOXIDE CONCENTRATIONS UNDER 30 PPM FOR ADDITIONAL INFORMATION ON CARBON MONOXIDE AND YOUR MEDICAL CONDI...

Page 18: ...rising to the ceiling so install the alarm in the middle of the ceiling where possible Ensure the alarm is within working distance of all corners of the room 4 If an alarm cannot be installed in the middle of a ceiling install at a distance of 20 inches 50cm away from the corners of the room 5 If an alarm is installed on a wall it should be at a distance of 4 12 inches 10 30 cm below the ceiling 6...

Page 19: ... that may transmit an RF signal as electronic noise may cause nuisance alarms Recommended Placement WARNING 1 THIS ALARM SHOULD BE INSTALLED BY A COMPETENT PERSON 2 INSTALLATION OF THE ALARM SHOULD NOT BE USED AS A SUBSTITUTE FOR PROPER INSTALLATION USE AND MAINTENANCE OF FUEL BURNING APPLIANCES INCLUDING APPROPRIATE VENTILATION AND EXHAUST SYSTEMS ...

Page 20: ... Mounting Steps 1 Mark three screw holes on the wall or ceiling according to the holes of the mounting bracket and drill the screw holes to a depth of 1 18 in 30 mm using a Ø 1 4 in 6 0 mm drill bit Then insert three plastic anchor plugs into the holes with a hammer 2 Attach the mounting bracket to the surface of the wall or ceiling with three screws and mount the alarm into the bracket by pushing...

Page 21: ... NOT DEACTIVATE THE ALARM UNIT UNTIL THE END OF LIFE SIGNAL HAS BEEN HEARD 2 ONCE THE MAXIMUM LIFETIME 10 YEARS IS REACHED THE ALARM WILL DELIVER 3 BEEPS EVERY 60 SECONDS 3 ONCE THE ALARM IS DEACTIVATED IT WILL NO LONGER FUNCTION IT CANNOT BE REACTIVATED AND MUST BE REPLACED To Deactivate the Alarm Pressing the Test Silence button can silence the end of life signal for up to 3 days 1 Peel back the...

Page 22: ... soft brush attachment once a month to remove dust and dirt 3 Never use detergents or other solvents to clean the unit 4 Avoid spraying air fresheners hair spray or other aerosols near the alarm 5 Do not paint the unit Paint will seal the vents and interfere with the sensor s ability to detect smoke CO Never attempt to disassemble the unit or clean inside Doing so will void your warranty 6 When re...

Page 23: ...and 5 times every 60 minutes during the next 4 days When the RF power supply is low the RF module will no longer work and the product will notinterconnect with other units It will still function as a standalone unit however FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to ...

Page 24: ...is device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Environmental Protection Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice Manufacturer and Service Information X S...