Insulation Blowing Machine M99
X-Floc Dämmtechnik-Maschinen GmbH
Page 19 of 51
Rosine-Starz-Straße 12 · 71272 Renningen · Germany
Phone +49-7159-80470-30 · Fax -40 | [email protected] · www.x-floc.com
5.2
Radio Remote Control FFB 400
39
3
8
43
44
45
46
40
41
42
Figure 14: Hand-held control and receiver FFB 400
Pos.
Control Element
Purpose
38
Material
Material and air flow activation, switching on the material flow
39
OFF
Material and air flow activation, switchover to parameterisation mode, key lock
activation
40
Antenna
Bidirectional radio transmission between hand-held control and receiver
41
Connection cable
Receiver and insulation blowing machine connection
42
Connection plug
Connection at the
machine control socket
X3 [28]
43
AUX
Additional-/reserve channel, deceleration time setting
44
Air
Air flow activation, material flow deactivation, setting the deceleration time
45
Radio contact LED
Control-LED for arising radio contact
46
Battery LED
Signal LED for necessary battery, radio demolition and activated key lock