12
Technical Support: [email protected] US: +1 866 677 0053 EU: +44 (0) 1793 230 343
Command
vw2 reset tx
Return
videowall2 reset tx
Note
Remove the video wall configuration of this tx and display a complete picture. (If this tx is in video wall mode, it
will only display part of the picture.)
Command
w2 pictureparam vw-name h-shift v-shift h-scale v-scale [TX/RX1 TX/RX2 ...]
Return
set videowall2 vw-name’s pictureparam: xx xx xx xx TX/RX1 TX/RX2 ...
Note
Configure the rx1/rx2/rx3 ... image shift. 1 unit = 8 pixels, a negative number indicates to move left or up).
Scale units = 1 Row or Columns / tearing delay units: μs, values between 10000~16000). If a parameter is
0 it will not be changed. TX/RX1, TX/RX2 are optional, if null, the whole video wall is corrected, otherwise
individual one or a selection TX/RX units are corrected.
E.g.: “vw2 pictureparam wall1 2 1 3 3 12500 Screen3 Screen4” will shift the image on screen 3 and 4 16 pix-
els down, 8 pixels right, whilst over-scaling by 3 rows and 3 columns and setting the tearing delay to 12500
μs.
Command
vw2 get
Return
videowall2 information is:
vw-name1
row-number1 TX1 RX11 RX12 ...
row-number2 TX2 RX21 RX22 ...
...
vw-name2
row-number1 TX3 RX11 RX12 ...
Note
Obtain video wall information from IP Control Box.
Command
vw2 bezelgap vw-name ow oh vw vh [TX/RX1 TX/RX2 ...]
Return
videowall2 vw-name’s bezelgap: xx xx xx xx TX/RX1 TX/RX2 ...
Note
Set the size of TV frame (video edge). TX/RX1, TX/RX2 are optional, if null, the whole video wall is corrected,
otherwise individual one or a selection TX/RX units are corrected.
E.g.: “vw bezelgap wall1 16100 9100 16000 9000”
Command
serial -b param –r {on|off} “command-string” hostname1 hostname2 ...
Return
serial command received: <cr>
serial -b param –r {on|off} “command-string” hostname1 hostname2 ...
Note
Configure devices hostname1, hostname2 to pass through serial command. Command-strings cannot con-
tain “ & ”.
-b param, configure the RS232 format of TX/RX and connected peripherals, including Baud rate, Data bits,
Parity and Stop bits.
E.g.: -b 115200-8n1.
-r {on|off}, to turn on & off Carriage Return following the command-string.
hostname1 hostname2 ..., indicates the destination, could be multiple.
E.g.: “serial –b 9600-8n1 –r on “PWR01” Screen1 Screen2 Screen3” Sends the command “PWR01” to
Screens 1, 2 & 3 with a carriage return at 9600 baud – 8 data bits, No parity, 1 Stop bit.
Command
N/A
Return
notify endpoint {+ | -} tx/rx tx/rx {- | +} tx/rx tx/rx ...
Note
Notify the third-party controller if any TX/RX is dropped out or added.
Serial
Pass-through the serial command.
Notification commands send by the NHD-IP-CTL
Notification of.
NETWORKHD CONTROL PROTOCOL