background image

6)

 

Failed, LED shows MIX FL  

 

 

Attention:  

1)

 

When the DIP switch is set to fixed EDID (1000---1111), the EDID COPY operation will 
fail.  The LED will show MIX FD.  

2)

 

Please insert or extract cables gently.  

 
SPECIFICATIONS  

Operating Temperature Range  

 

 

 

-5 to +35°C (-41 to +95 °F) 

Operating Humidity Range    

 

 

 

5 to 90 % RH (no condensation)  

Input Video Signal    

 

 

 

 

0.5-1.0 volts p-p  

Input DDC Signal      

 

 

 

 

5 volts p-p (TTL)   

Video Format Supported   

 

 

 

 

DTV/HDTV: 1080P/1080i/   

 

 

 

 

 

 

 

 

720P/576P/480P/576i/ 480i   

Audio Format Supported  

 

 

 

 

DTS-HD.Dolby tureHD.7.1ch  

Output Video   

 

 

 

 

 

HDMI1.2 and HDMI 1.3  

Maximum Transmission Distance     

<15m (If needed, HDMI extender is 
optional)   

UTP cable Transmission Distance  

<40m (use Wyrestorm UTP receiver, 
if need longer distance, Wyrestorm 
UTP repeater should be used)  

Power Consumption    

 

 

 

 

35wtts (Max)  

Dimensions    

 

 

 

 

 

282.58mmD×438.15mmW×141.2mmH/ 

 

 

 

 

 

 

 

 

11.125''D×17.25''W×5.56''H

 

Mass (Main Unit)  

 

 

 

 

 

3.4kg 

 

*Note: Specifications are subject to change without notice. Mass and dimensions are 
approximate. 

Summary of Contents for MAT8T820

Page 1: ...a set of dual RJ 45 connecters as the second mirrored HDMI output The two outputs work simultaneously The UTP output supports both dual and single cat5e cat6 4 Reading and saving EDID function from di...

Page 2: ...NY KIND 2 DO NOT INSTALL OR PLACE THIS UNIT IN A BOOKCASE BUILT IN CABINET OR IN ANY OTHER CONFINED SPACE MAKE SURE THE UNIT IS WELL VENTILATED 3 TO PREVENT RISK OF ELECTRIC SHOCK OR FIRE HAZARD DUE T...

Page 3: ...RS485 LAN and supplied remote control IR emitters in the matrix are for controlling the sources the IR control signal could be from remote locations via STP UTP type HDMI connection on the rear panel...

Page 4: ...MBER Abbreviation as P N PANEL DESCRIPTIONS Front panel 1 Power switch 2 Output selection push button Use it to choose the output channel you want to change 3 LED indicator of input for output port 1...

Page 5: ...ON 1 Connect the HDMI input sources such as HD DVD PS3 STB etc into MAT8T820 2 Connect the standard HDMI outputs such as HD LCD HD DLP into MAT8T820 3 Connect two CAT 5E cables to both the STP UTP out...

Page 6: ...ix is ready 9 Turn on the displays you want to watch 10 Use the remote supplied or push the button on the front panel to choose input source or using infrared extension receiver RS232 RS485 or LAN por...

Page 7: ...3 Press the Enter button to confirm the action Then the LED stops blinking...

Page 8: ...Control via RS232 The Interface of MAT8T820_COMCTL The Message Window...

Page 9: ...p 4 or send Control Command see 2 3 to MAT8T820 it will send out the message about operation results as seen below Status Button Click this button to read the status of MAT8T820 The status displays wh...

Page 10: ...it will read the current mode of MAT8T820 if you want to change the mode select the mode you want and click OK Set IP button Click this button to set IP address for NETCTL The Com Status Connect stat...

Page 11: ...nd format 1 Below are data format and baud rate setting for writing independent software Com port setting Baud Rate 9600 bps Data bits 8 bits Parity None Stop bits 1 bit Flow control None The command...

Page 12: ...ort6 58 59 1 50 2 51 3 52 4 53 5 54 6 55 7 56 8 57 Outport7 68 69 1 60 2 61 3 62 4 63 5 64 6 65 7 66 8 67 Outport8 78 79 1 70 2 71 3 72 4 73 5 74 6 75 7 76 8 77 When you send a control command to the...

Page 13: ...6 7 8 9 10 11 12 13 14 15 16 r n s X1 X2 s X3 X4 s X5 X6 s X7 X8 r n The status has 16 bytes X1 X2 X3 X4 X5 X6 X7 X8 separately stands for the related input chosen by the output X1 stands for the outp...

Page 14: ...TL run on PC at the first time it will create a file NETCTL TXT This file is for device information s backup This information includes MAC address of MAT8T820 IP address device name etc Double click N...

Page 15: ...Double click the device name or right click and click the open A web browser will be shown The default password is 0000000000 input the password and login The device controller page will be displayed...

Page 16: ...e controller The left area shows which input ports are being chosen by the output ports 4 When Assign IP is displayed it means that the device has not been assigned IP automatically Double click this...

Page 17: ...as static IP Use the Assign IP function when the automatically obtain IP address fails This assigned IP address is not saving in flash 11 IR call back from remote locations to control the HDMI Matrix...

Page 18: ...of RJ45 on OUTPUT1 will choose TX IR3 to send the signal out 9 DIP switch setting Position ID 1 2 3 4 UTP output mode and EDID 0 1 0 0 Dual UTP Fully COPY 0 1 0 1 Single UTP Fully COPY 0 1 1 0 Dual UT...

Page 19: ...2 Under MAT8T820 s normal working condition push ENTER and OUTPUT_N simultaneously within two seconds will see the LEDs lit the character circularly Means the EDID COPY is auto running Just release th...

Page 20: ...Means the matrix is performing EDID COPY Release the buttons waiting the machine finish the remained work 4 If the EDID COPY succeeds the LEDs will show MIX OK otherwise the LEDs will display MIX FL T...

Page 21: ...ts p p TTL Video Format Supported DTV HDTV 1080P 1080i 720P 576P 480P 576i 480i Audio Format Supported DTS HD Dolby tureHD 7 1ch Output Video HDMI1 2 and HDMI 1 3 Maximum Transmission Distance 15m If...

Page 22: ...esult in fire electric shock or other hazards 4 Safety check After repairs or service ask the servicer to perform safety checks to confirm that the unit is in proper working condition WARRANTY If your...

Page 23: ...amage The Limited Warranty ALSO DOES NOT COVER failures which are caused by products not supplied by the warrantor or failures which result from accidents misuse abuse neglect mishandling misapplicati...

Page 24: ...te your business Please contact us with your question and comments WyreStorm 6755 Buckles Cove Memphis TN 38133 1 877 HDMI WYRE Toll Free 901 363 0111 Office Phone 901 363 0115 Office Fax Email info w...

Reviews: