Seite 26 von 53 Seiten
Blinking rapidly
Blinking slowly
Continuously
ON
LED red
Sender/Receiver ON
Power for sensor ON
Power for sensor
only ON
Not enough
battery power
LED green
Data transmission
(sending/receiving)
Connector
Cable connection to LEVELMETER for conventional transmission
of data
ON / OFF
Measuring instrument and data transmission ON/OFF
Display for 902MHz (USA)
see page 48
Channel
switch
6 Channels are available:
The same channel is required for the instruments connected
together
In case of transmission problems another channel may be chosen.
The originally used channel may be occupied by another user.
Switch ON the
instrument
•
press once only the button <ON/OFF> the instrument and the sender/receiver
starts to work. The red LED is blinking rapidly
•
with another short push to the button the sender/receiver may be stopped. Local
measurement with the instrument only. The red LED is blinking slowly.
•
with another short push to the button the sender/receiver is activated again
Switch OFF the
instrument
•
Press the button <ON>/<OFF> a few seconds until the red LED has stopped
blinking.
IMPORTANT:
When an instruments address is to be changed only the one respective
instrument can be active